16
Advanced settings
16.1
Learn with advanced setting of “back- and latch-check”
See the prerequisites for performing a “learn” under the heading Auto-learn – automatically sets
back and latch check (recommended) on page 56.
a Push the button once or twice as for auto-setting.
b Stop the door at required back-check.
c The door reverts towards closed position.
d Remove the stop.
e Stop the door at required latch-check.
f
The door reverts to learn the fully open position.
g Remove the stop.
h The door reverts to closed position.
16.2
Revert to default values for “back- and latch-check”
a Disconnect batteries if any.
b Disconnect the mains contact.
c Press the LEARN BUTTON and keep it depressed.
d Connect the mains contact.
e Watch the ERROR LED.
3 s
f
Release the LEARN BUTTON after 3 seconds (LED is out).
g The BACK CHECK, LATCH CHECK and OPEN POSITION have now reverted to default values.
h Disconnect the mains contact.
i
Next time the mains is connected, the operator will use the default values.
65
Issue 2014-11-24
1005088-EMEI-11.0
16 Advanced settings