8.4
Fastening requirements
Minimum requirements of wall profile*
Base material
5 mm **
Steel
6 mm **
Aluminium
min. 50 mm from the underside
Reinforced concrete
50 mm
Wood
Expansion shell bolt, min. M6x85, UPAT PSEA B10/25, min. 50
mm from the underside
Brick wall
* EM minimum recommended requirements. Building Codes may give different specifications.
Refer to AHJ (Authority Having Jurisdiction).
** Thinner wall profiles must be reinforced with rivnuts.
8.5
Tools required
• Torx T10
• Metric Allen wrenches 2,5; 3; 4 and 6 mm
• Flatblade screwdriver (potentiometer and terminal size)
• Screwdriver (Philips size 2)
• Nut driver, 5 mm
• Carpenter’s level
• Tape rule
• Power drill and set of drill bits
• Center punch
• Wire stripper
• Silicone sealant
• Installation and Service Manual (this manual)
8.6
Installation on double doors
If the operators are to be mounted at the same height with pushing and pulling arm systems, the
height is determined by the pulling arm system, PULL. The pushing arm system PUSH must always
have a shaft extension, minimum 50 mm, maximum 70 mm to match the mounting heights visually.
Example: if PULL has a 20 mm extension, the PUSH must have a 70 mm extension. If PULL has 0 mm
extension, the PUSH must have a 50 mm extension.
For installation, follow the instructions for the applicable arm system.