10
Electrical connection
Note! During any work with the electrical connections the mains power must be disconnected.
• Place the electric switch easily accessible from the operator. If a plug contact is used in the in-
stallation the wall socket shall be placed easily accessible from the operator.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
10.1
Mains connection
a Switch off the mains power.
b Assemble the bottom end plates and tighten the two screws firmly.
c Connect the plug contact to the wall socket or connect to the mains switch.
Note! The mains switch must be connected according to national regulation.
d Connect the mains contact to the operator.
Mains power:100-240 V AC – 50/60 Hz
Alt. 1
ILL-01626
Mains contact
Alt. 2
ILL-02023
1
1
0
0
PE = Yellow/Green
L = Brown
N = Blue
10AT
Mains contact
Symbol shown to ensure that the manual is read before the installation starts.
PE = Yellow/Green
L = Brown
N = Blue
49
Issue 2014-11-24
1005088-EMEI-11.0
10 Electrical connection