11
Start-up
The spring pre-tension is factory set to 210° and is normally not necessary to adjust. If adjustment
has to be carried out, see page 66.
11.1
Adjusting the door stop
a Close the door.
b Turn the potentiometer SPTE to 0° (if not already on 0°).
CU-ESD
0°
SPTE
c Switch on the mains power (the operator will find its closed position).
0
0
d Open the door to required open position, plus approx. 5/8” (15 mm), by turning the poten-
tiometer SPTE on the CU-ESD, clockwise.
0°
SPTE
≈ 95°
1005088-EMEI-11.0
Issue 2014-11-24
54
11 Start-up