Enterasys X-Pedition 8000/8600 Getting Started Guide
69
Installing the Hardware
Installing the Switching Fabric Module (X-Pedition 8600 only)
On the X-Pedition 8600, the switching fabric module is shipped separately from the X-Pedition
chassis. To install or replace the primary switching fabric module, or if you want to install a
redundant switching fabric module, use the following procedure. You will need a #2 Phillips
screwdriver to perform this procedure.
The primary switching fabric module must be installed in slot Fabric 1. The redundant switching
fabric module must be installed in slot Fabric 2.
Figure 33
shows an example of how to install a
switching fabric module. The procedure following the figure describes how to do this.
Figure 33. Installing a switching fabric module on the X-Pedition 8600
To Install a Switching Fabric Module
1.
If a coverplate is installed over the switching fabric module slot (slot Fabric 1 or Fabric 2), use
the #2 Phillips screwdriver to remove the coverplate.
2.
Slide the switching fabric module all the way into the slot, firmly but gently pressing to ensure
that the pins on the back of the module are completely seated in the backplane.
6
4
2
7
5
3
CM/1
PS2
PS1
CM
SSR-16
1000BASE-SX
12
10
8
13
11
9
14
15
Fabric 1
Fabric 2
SSR-CM2-64
CONTROL MODULE
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
10/100BASE-TX
SSR-HTX22-08-AA
10/100BASE-TX
SSR-HTX22-08-AA
1000BASE-LX
SSR-GLX29-02-AA
8
7
6
5
4
3
2
1
100BASE-FX
SSR-HFX21-08-AA
2
1
1000BASE-LX
SSR-GLX19-02
SSR-GSX11-02
1000BASE-SX
SSR-GLX29-02-AA
2
1
8
7
6
5
4
3
2
1
10/100BASE-TX
SSR-HTX22-08-AA
8
7
6
5
4
3
2
1
10/100BASE-TX
SSR-HTX22-08-AA
8
7
6
5
4
3
2
1
100BASE-FX
SSR-HFX21-08-AA
8
7
6
5
4
3
2
1
10/100BASE-TX
SSR-HTX22-08-AA
2
1
Switching Fabric
8
7
6
5
4
3
2
1
10/100BASE-TX
SSR-HTX22-08-AA
SSR-CM2-64
CONTROL MODULE
8
7
6
5
4
3
2
1
10/100BASE-TX
SSR-HTX22-08-AA
8
7
6
5
4
3
2
1
10/100BASE-TX
SSR-HTX22-08-AA
PWR
SSR-PS-16
SN
100-125V~ 10A
200-240V~ 6A
50/60 Hz
TO REMOVE POWER TO
UNIT DISCONNECT ALL
POWER SUPPLY CORDS
PWR
SSR-PS-16
SN
100-125V~ 10A
200-240V~ 6A
50/60 Hz
TO REMOVE POWER TO
UNIT DISCONNECT ALL
POWER SUPPLY CORDS
Switching Fabric
SSR-SF-16
SSR-SF-16
Summary of Contents for 8000/8600
Page 1: ...Getting Started Guide Revision Date 11 27 2002 8000 8600 9032552 16...
Page 8: ...vi Enterasys X Pedition 8000 8600 Getting Started Guide...
Page 116: ...104 Enterasys X Pedition 8000 8600 Getting Started Guide...
Page 142: ...Index 130 Enterasys X Pedition 8000 8600 Getting Started Guide...