background image

Enterasys X-Pedition 8000/8600 Getting Started Guide

33

Hardware Overview

SSR-GLX70-01-AA and SSR-GLH39-02

The SSR-GLX70-01-AA and SSR-GLH39-02 line cards are similar to the SSR-GLX39-02 line 
card, but extend the transmission distance over single mode fiber (SMF) to 70 kilometers for 
Gigabit Ethernet. 

Figure 11

 shows the front panel of the 1000BASE-LLX line card.

Figure 11. Front panel of 1000BASE-LLX line card

Figure 12

 shows the front panel of the 1000BASE-LLX (T-Series) line card.

Figure 12. Front panel of 1000BASE-LLX (T-Series) line card

LEDs

Hot

Swap

1

Online

Offline

Rx

Tx Link

AN

Gigabit

 

port

1000BASE-LLX

SSR-GLX70-01-AA

2

1

Link

Offline

Online

Tx

Rx

1000BASE-LLX

SSR-GLH39-02

Hot

Swap

Link

Tx

Rx

AN

AN

Gigabit Port

Gigabit Port

Table 7. SSR-GLX70-01-AA and SSR-GLH39-02 line card LEDs

LED

Condition

Description

Offline

Amber

The line card is offline (powered off) but is ready for hot 
swap.

The Offline LED also is lit briefly during a reboot or reset of 
the X-Pedition but goes out as soon as the control module 
discovers the line card.

Online

Green

The line card is online and is ready to receive, process, and 
send packets if configured to do so.

Summary of Contents for 8000/8600

Page 1: ...Getting Started Guide Revision Date 11 27 2002 8000 8600 9032552 16...

Page 2: ...HIS DOCUMENT WEB SITE OR THE INFORMATION CONTAINED IN THEM EVEN IF ENTERASYS NETWORKS HAS BEEN ADVISED OF KNEW OF OR SHOULD HAVE KNOWN OF THE POSSIBILITY OF SUCH DAMAGES Enterasys Networks Inc 35 Indu...

Page 3: ...wn expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment INDUST...

Page 4: ...60825 European Committee for Electrotechnical Standardization When operating within their performance limitations laser transceiver output meets the Class 1 accessible emission limit of all three stan...

Page 5: ...States pursuant to the License Exception CIV under the U S Export Administration Regulations You agree that You are a civil end user of the Program and agree that You will use the Program for civil e...

Page 6: ...MATERIALS AND ANY ACCOMPANYING HARDWARE 7 NO LIABILITY FOR CONSEQUENTIAL DAMAGES IN NO EVENT SHALL ENTERASYS OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES...

Page 7: ...epresentative Address Enterasys Networks Ltd Nexus House Newbury Business Park London Road Newbury Berkshire RG14 2PZ England Conformance to Directive s Product Standards EC Directive 89 336 EEC EC Di...

Page 8: ...vi Enterasys X Pedition 8000 8600 Getting Started Guide...

Page 9: ...are Specifications 53 Installing the Hardware 55 Chapter 3 Software Installation and Setup 83 Installing a PCMCIA Flash Card 84 Powering On and Booting the Software 86 Starting the Command Line Interf...

Page 10: ...1 04 111 SSR GLX70 01 AA and SSR GLH39 02 112 SSR GSX21 02 AA and SSR GLX29 02 AA 113 SSR GSX31 02 114 SSR GTX32 04 and SSR GTX32 02 115 SSR HFX21 08 AA and SSR HFX29 08 AA 116 SSR HSSI 02 CK 117 SSR...

Page 11: ...on page xii What s New Changes to this manual include the addition of new and extended capabilities for the following Line Cards on page 20 Control Modules on page 14 External Controls on page 15 Inst...

Page 12: ...tallation Install the X Pedition 8000 or X Pedition 8600 software boot the software and set up the unit Chapter 3 Software Installation and Setup Troubleshoot installation problems Appendix A Troubles...

Page 13: ...If you want to skip this information and install the X Pedition now see Chapter 2 Hardware Installation If you want to boot the X Pedition software and perform basic configuration tasks now see Chapt...

Page 14: ...20 000 Layer 2 security and access control filters Up to 16 MB input output buffering per Gigabit port 1 MB input output buffering per 10 100 port 20 MB shared input output buffering across WAN ports...

Page 15: ...affic to specific chassis slots line cards Hot swapping Line cards Control module when redundant control module is installed and online Switching Fabric Modules X Pedition 8600 only when redundant swi...

Page 16: ...Pedition 8000 8600 Getting Started Guide TCP UDP Services The following table lists some well known TCP UDP services provided by the X Pedition TCP Port UDP Port Description 23 Telnet 161 SNMP 67 BOOT...

Page 17: ...xit port s for the bridged packet If the packet is addressed to the X Pedition s own MAC address the packet is routed rather than bridged Flow based bridging The X Pedition performs this type of bridg...

Page 18: ...any corporate intranets Internet Packet Exchange IPX protocol by Novell used in NetWare products Appletalk protocol used to allow users of dissimilar computer systems to share information over a netwo...

Page 19: ...s the following IPX routing protocols IPX RIP a version of the Routing Information Protocol RIP tailored for IPX IPX SAP the Service Advertisement Protocol which allows hosts attached to an IPX networ...

Page 20: ...raffic based on source MAC address Layer 2 destination filters block bridge traffic based on destination MAC address Layer 2 flow filters block bridge traffic based on specific source destination pair...

Page 21: ...RMON v2 Statistics Statistics for TCP and UDP NetFlow The export of flow accounting statistics Management Platforms You can manage the X Pedition using the following management platforms Command Line...

Page 22: ...rom 0 to 7 Slot 0 is in the lower left corner of the chassis and slot 7 is in the upper right corner Figure 1 Front view of a fully loaded X Pedition 8000 chassis 2 1 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2...

Page 23: ...6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 10 100BASE TX SSR HTX22 08 AA 10 100BASE TX SSR HTX22 08 AA 10 100BASE TX SSR HTX22 08 AA 10 100BASE TX SSR HTX22 08 AA 1000...

Page 24: ...d line cards together The power supplies use the backplane to provide power to the rest of the system The line cards and control modules use the backplane to exchange control information and packets T...

Page 25: ...fan tray completely into the slot Fans will start up and the LED on the front of the fan tray will light if the fan is installed properly Once the fan tray is installed the following message is displa...

Page 26: ...lot is active The control module cannot use two PCMCIA flash cards at the same time Boot Flash The control module has a boot flash containing the X Pedition s boot software and configuration files The...

Page 27: ...rt to establish a management connection to the X Pedition over a local or bridged Ethernet segment Reset switch RST Use this switch to reboot the X Pedition s CPU PCMCIA flash memory slots These slots...

Page 28: ...supply has its own internal cooling fan The vent on the front of the power supply is the inlet vent for the cooling fan Figure 4 shows the front view of an X Pedition 8000 AC power supply Figure 4 Fro...

Page 29: ...e LED is lit the power supply is connected to an appropriate power source and is active The status LED is lit when you switch the power supply on not when you plug the power supply into a power source...

Page 30: ...sting of a positive terminal negative terminal and a safety ground The DC supply is designed to be powered by a 48 Volt DC source Figure 7 shows the front view of an X Pedition 8600 DC Power Supply Fi...

Page 31: ...ule in the slot labelled Fabric 2 serves as a redundant switching fabric module Figure 8 shows the front panel of the X Pedition 8600 Switching Fabric module Figure 8 Front panel of X Pedition 8600 Sw...

Page 32: ...ithin an IEEE 802 3 frame indicates less than 46 bytes of data The X Pedition removes the length field information of incoming IEEE 802 3 802 2 and Ethernet SNAP packets then recalculates the field pr...

Page 33: ...terconnecting IP networks over an ATM backbone is done by many service provider and enterprise customers The OC 3c module provides the vital link between the network s switch router solutions and the...

Page 34: ...the following PHY interface modules Port type Specification APHY 67 1 DS 3 T 3 interface BNC Coax see APHY 67 and APHY 77 on page 81 for attaching cables 75 coaxial RG 59B or equivalent terminated wi...

Page 35: ...AA 62 5 125 m Maximum cable length cannot exceed 2 kilometers maximum will allow up to three cables two splices Additional cables splices will reduce the maximum cable length 0 to 9 dB loss at 1300 nm...

Page 36: ...om Unit is operational Port 1 Traffic 2 Tx Green Top Indicates when the transceiver receives packets Rx Green Bottom Indicates when the transceiver receives flow control packets Port 2 Traffic 2 Tx Gr...

Page 37: ...CM4 targeted for applications that require higher processing power uses a 380Mhz RISC processor and detection circuitry to maximize the internal clock speed for the given chassis Port 1 10 100 BaseT M...

Page 38: ...available for point to point connections with only two stations on a FDDI ring that support full duplex The SSR FDDI 02 module also supports the ring and DEC ring purger protocols an extension to the...

Page 39: ...dby Red Diagnostic failure Primary Secondary Port LEDs A B P S A B P S Yellow Yellow Off Off Port enabled not active Off Off Off Off Ports disabled Green Green Off Off Ports enabled Green Green Green...

Page 40: ...ot swap The Offline LED also lights briefly during a reboot or reset of the X Pedition but goes out as soon as the control module discovers the line card Online Green The line card is online and is re...

Page 41: ...and half duplex Amber intermittent Auto Negotiation is in process Amber solid Indicates a problem with Auto Negotiation configuration Red Indicates an Auto Negotiation failure This fault may occur if...

Page 42: ...undant power configuration or only one power supply you will not be able to support more than 4 SSR GLX39 04 and SSR GSX31 04 cards in the X Pedition 8000 and 10 in the X Pedition 8600 Ports 4 1000BAS...

Page 43: ...256 000 memory size 16 MB Switch Method Address based and Flow based Queue Buffer Input packet memory size 8 MB Output packet memory size 8 MB Physical Dimensions Size 3 94 cm H x 19 68 W x 27 94 D 1...

Page 44: ...e port received an error during operation Red The port hardware detected a cable plugged into the port but a bad link was established Off No link from the port exists Per port Rx Green The port s tran...

Page 45: ...e card Figure 12 Front panel of 1000BASE LLX T Series line card LEDs Hot Swap 1 Online Offline Rx Tx Link AN Gigabit port 1000BASE LLX SSR GLX70 01 AA 2 1 Link Offline Online Tx Rx 1000BASE LLX SSR GL...

Page 46: ...a flow control packet Per port Tx Green The port s transceiver transmitted a packet Amber The port s transceiver transmitted a flow control packet Per port AN Green Green indicates that the line card...

Page 47: ...is ready for hot swap The Offline LED also lights briefly during a reboot or reset of the X Pedition but goes out as soon as the control module discovers the line card Online Green The line card is on...

Page 48: ...half duplex Amber intermittent Auto Negotiation is in process Amber solid Indicates a problem with Auto Negotiation configuration Red Indicates an Auto Negotiation failure This fault may occur if the...

Page 49: ...The Offline LED also is lit briefly during a reboot or reset of the X Pedition but goes out as soon as the control module discovers the line card Online Green The line card is online and is ready to r...

Page 50: ...plex Amber intermittent Auto Negotiation is in process Amber solid Indicates a problem with Auto Negotiation configuration Red Red indicates an Auto Negotiation failure This fault may occur if the lin...

Page 51: ...GTX32 04 Figure 15 Front panel of SSR GTX32 04 line card Note If your system uses a redundant power configuration or only one power supply you will not be able to support more than 5 SSR GTX32 04 and...

Page 52: ...so Offline On Amber The module is offline powered down and ready to hot swap Per Port Transmit Green The port transmitted a packet Amber The port transmitted a flow control packet Per Port Receive Gre...

Page 53: ...line card LEDs LED Condition Description Offline Amber When lit this amber LED on the left side of the line card indicates that the line card is offline powered off but is ready for hot swap The Offl...

Page 54: ...yer 2 3 and 4 switching allowing for consistent policy management for security and quality of service Detailed accounting information can be gathered using per PVC RMON enabling easy confirmation that...

Page 55: ...ED Indicators LED Condition Status Online 2 Green The unit is operational and functioning properly Offline 2 Amber The unit is not operational You may remove the unit from the chassis Tx 4 Amber A fra...

Page 56: ...HTX22 08 AA line card LEDs LED Condition Description Offline Amber The line card is offline powered off and is ready for hot swap The Offline LED also is lit briefly during a reboot or reset of the X...

Page 57: ...on Offline Amber The line card is offline powered off and is ready for hot swap The Offline LED also lights briefly during a reboot or reset of the X Pedition and goes out as soon as the control modul...

Page 58: ...s to a POS OC 3c line card obtain an MT RJ cable and plug one end into the port connector Plug the other end into the port of the other device Since MT RJ cables consist of only one line there are no...

Page 59: ...d ready to receive process and send packets if configured to do so Offline Amber The module is offline powered down and ready to hot swap Transmit Green The port transmitted a packet Red The port tran...

Page 60: ...SC style Media Interface Connectors MICs to attach to multimode fiber MMF and single mode SMF cables Figure 21 shows an SSR POS39 02 line card Figure 21 SSR POS39 02 line card Note If your system uses...

Page 61: ...ckets if configured to do so Offline On Amber The module is offline powered down and ready to hot swap Transmit Green The port transmitted a packet Red The port transmitted a flow control packet Recei...

Page 62: ...LEDs 1 2 Tx Rx Link Quad Serial C SSR SERCE 04 AA 1 2 3 4 Tx Rx Link 3 4 Online Offline Hot Swap Table 17 SSR SERCE 04 AA and SSR SERC 04 AA line card LEDs LED Condition Description Offline Amber The...

Page 63: ...oduct cautions to avoid personal injury or product damage Preventing Injury Cautions Observe the following safety warnings to prevent accidental injury when working with the Enterasys X Pedition X Ped...

Page 64: ...and fiber optic ports are shipped with protective caps to prevent contamination To avoid contamination replace port caps on all fiber optic devices when not in use Cable assemblies and fiber optic po...

Page 65: ...bove do not apply For questions related to power consumption please contact Enterasys Networks X Pedition 8000 X Pedition 8600 Dimensions 8 75 in H x 17 25 W x 12 25 D 22 3 cm H x 43 82 W x 31 12 D 19...

Page 66: ...10 2 70 SSR HTX12 08 AA SSR 8 Port Fast Ethernet TX UTP 4 MB line card 5 90 1 60 SSR HTX22 08 AA SSR 8 Port Fast Ethernet TX UTP 16 MB line card 5 90 1 60 SSR HTX32 16 SSR 16 Port Fast Ethernet TX 16...

Page 67: ...t to ensure that everything you ordered arrived securely Caution To avoid back strain be careful when lifting the chassis out of the shipping box Open the shipping box es and verify that you received...

Page 68: ...ecommends that only qualified personnel conduct installation of any X Pedition chassis This section contains procedures for the following types of installation Tabletop Installation Rack mount Install...

Page 69: ...ssis easier install the chassis before you install line cards or redundant control modules and power supplies To install the X Pedition chassis in an equipment rack use the following procedure You nee...

Page 70: ...ce the primary AC power supply or if you want to install a redundant power supply use the following procedure You will need a 2 Phillips screwdriver to perform this procedure Note Use a single phase g...

Page 71: ...2 If a coverplate is installed over the power supply slot use the 2 Phillips screwdriver to remove it If you are replacing an AC power supply unplug the power cable from the supply you are replacing...

Page 72: ...onnect to a reliably grounded SELV source 2 The branch circuit over current protection must be rated at a maximum of 20A for the X Pedition 8000 and 40A for the X Pedition 8600 3 Use 14 AWG solid copp...

Page 73: ...he DC power supply all the way into the slot firmly but gently pressing to ensure that the pins on the back of the power supply are completely seated in the backplane 4 Use a 2 Phillips screwdriver to...

Page 74: ...he front view of an X Pedition 8600 DC power supply Figure 26 Front view of an X Pedition 8600 DC power supply The X Pedition 8600 DC power supply has a five terminal wiring block on the front panel T...

Page 75: ...lugs on X Pedition 8600 DC power supply Note For the X Pedition 8600 to work properly both positive terminals and both negative terminals of the X Pedition 8600 DC power supply MUST be connected to th...

Page 76: ...source and then tie the X Pedition 8600 s wiring lugs together to and to See Figure 29 Figure 29 Tying X Pedition 8600 DC supply lugs together From 48 Volt Source From 48 Volt Source Conductive Split...

Page 77: ...Figure 30 Installing a Control Module To install the control module 1 If a coverplate is installed over the control module slot slot or CM 1 only use the 2 Phillips screwdriver to remove it 2 Slide th...

Page 78: ...te If the X Pedition chassis contains a redundant Control Module you do not need to power down the X Pedition You must however press the Hot Swap button before removing the Control Module CAUTION Befo...

Page 79: ...dition memory slot 5 Insert the SSR MEM 128 into an empty memory slot Gently press the memory card in place and ensure that the card is completely seated in the slot Note Slot P7 must contain the larg...

Page 80: ...n place to ensure that the pins on the back of the line card are completely seated in the backplane 8 Tighten captive screws Align the captive screws with the holes in the face of the module and tight...

Page 81: ...ve the coverplate 2 Slide the switching fabric module all the way into the slot firmly but gently pressing to ensure that the pins on the back of the module are completely seated in the backplane 6 4...

Page 82: ...s between the card guides as shown in Figure 30 on page 65 Check both the upper and lower tracks 3 Lock down the left and right metal tabs to secure the switching fabric module to the chassis 4 Use th...

Page 83: ...cial Instructions SSR ARE Note The SSR ARE is designed for the X Pedition 8000 8600 only do not try to install these modules in any other units Do not install the SSR ARE in slot 0 or 1 on the X Pedit...

Page 84: ...ardware System show version System show bootlog SSR FDDI 02 3 2 0 0 Preparing the Module Before installing the module you must install at least one of the following FPHYs purchased separately FPHY 01...

Page 85: ...e following from Enable mode to enter Configuration mode Enable Configure 2 You may now begin configuring ports on the SSR GLX39 04 or SSR GSX31 04 Refer to the Enterasys X Pedition Command Line Inter...

Page 86: ...he cable are not properly engaged The copper cable did not click into place or is not properly seated Helpful CLI Commands for Debugging System show hardware System show version System show bootlog SS...

Page 87: ...ul CLI Commands for Debugging System show hardware System show version System show bootlog SSR POS39 02 SSR POS31 02 9 0 0 2 Note If your system uses a redundant power configuration or only one power...

Page 88: ...at contains the line card and y is a specific port number on the card System show bootlog SSR SERCE 04 AA E8 3 0 0 CLI Setup Enter the following command at the CLI before implementing any configuratio...

Page 89: ...require the following tools Hot Swap You may install most modules into a live system without powering off the device However do not remove an active module from a live system except under the followin...

Page 90: ...etween the card guides as shown in Figure 34 Note Make sure that the circuit card is between the card guides Check both tracks Figure 34 Installing a line card 3 Slide the line card all the way into t...

Page 91: ...Networks FDDI products Installing the FDDI PHY Cards Each FDDI line card has two slots available for PHY cards One FDDI PHY card can be installed into each available slot The following procedure descr...

Page 92: ...the figure describes how to do this Figure 35 Installing an ATM PHY card To install a PHY card into an ATM line card 1 Use a Phillips screwdriver to loosen the two captive screws that hold the option...

Page 93: ...APHY 82V card 1 Align the key of the modular jack MJ plug with the locking key of the MJ receptacle 2 Push the MJ plug into the receptacle until the plug mates fully with the locking key You will hea...

Page 94: ...h the receive port Insert the connectors ensuring that the key is correctly positioned APHY 22 To attach the segment cables to your APHY 22 card 1 Align the key of the modular jack MJ plug with the lo...

Page 95: ...the software Starting the Command Line Interface CLI Setting basic system information Setting up SNMP community strings Setting up passwords Setting the DNS domain name and address Setting SYSLOG para...

Page 96: ...A card while the X Pedition is running 2 Insert the PCMCIA card into the upper slot on the control module pressing firmly to ensure that the card is fully seated Figure 36 Install a PCMCIA flash card...

Page 97: ...to boot up but stop after a few seconds leaving the router in boot mode If the X Pedition does not display the external flash card absent message the router did not find an image to load from the PCM...

Page 98: ...utomatically power on and attempt to boot using the software image in the motherboard s boot flash While the software is booting the HBT heartbeat LED on the chassis flashes When the software finishes...

Page 99: ...e first enter Enable mode enable command then enter the configure command from the Enable command prompt When you are in Configure mode the command prompt ends with config Boot This mode appears when...

Page 100: ...CLI commands Key sequence Command Ctrl A Move cursor to beginning of line Ctrl B Move cursor back one character Ctrl D Delete character Ctrl E Move cursor to end of line Ctrl F Move cursor forward on...

Page 101: ...cute the commands Instead the X Pedition checks the syntax of the commands and if they are syntactically correct stores them in a temporary scratchpad in memory The scratchpad is automatically cleared...

Page 102: ...e a Ensure that you are in Enable mode by entering the enable command in the CLI b Enter the copy active to startup command The CLI displays the following message c Enter yes or y to add the active co...

Page 103: ...Because the X Pedition is not yet running a routing protocol the target IP address must be attached to the router locally You may not specify a target that is connected to the X Pedition by another r...

Page 104: ...otocol multi user accounting no longer requires TACACS or RADIUS The default password for each access level is blank Simply press Enter or Return without entering a password If you want to add passwor...

Page 105: ...e the X Pedition does not have a command for displaying passwords If you forget a password you can remove the password by entering the following command while in Configure mode See the Enterasys X Ped...

Page 106: ...for which the DNS server s have authority 6 Use the system set dns server command to add one or more DNS servers to the X Pedition Note If you specify more than one IP address you must separate the a...

Page 107: ...SYSLOG server To specify the SYSLOG server and the types of messages you want the CLI to log on the server use the following procedure 1 Enter the enable command in the CLI to enter Enable mode 2 Use...

Page 108: ...X Pedition is set to use the factory installed system software in the motherboard s internal flash chip 3 Copy the software upgrade you want to install onto a TFTP server that the X Pedition can acce...

Page 109: ...rboard s internal flash chip 2 Copy the boot firmware upgrade you want to install onto a TFTP server that the X Pedition can access Use the ping command to verify that the X Pedition can reach the TFT...

Page 110: ...ful execution the X Pedition scratchpad simplifies system configuration by allowing you to enter configuration commands in any order even when dependencies exist When you activate the commands in the...

Page 111: ...configuration 1 Enter the enable command in the CLI to enter Enable mode 2 Enter the system show active config command to display the status of each command line The CLI displays the active configura...

Page 112: ...Activating Configuration Changes and Saving the Configuration File 100 Enterasys X Pedition 8000 8600 Getting Started Guide...

Page 113: ...ts no activity no LEDs are on the fan module is not operating and so on Make sure the power supply is installed and plugged into a power source and the power source is active Also check to see whether...

Page 114: ...ou have properly connected the primary control module to a management console and the console is powered on An older software version continues to boot instead of the newer version on a PCMCIA card or...

Page 115: ...cess the X Pedition Use the procedure in Setting Up SNMP Community Strings on page 91 to set up an SNMP community string and specify a target for SNMP traps If you have already performed this procedur...

Page 116: ...104 Enterasys X Pedition 8000 8600 Getting Started Guide...

Page 117: ...on page 110 SSR GLX39 04 and SSR GSX31 04 on page 111 SSR GLX70 01 AA and SSR GLH39 02 on page 112 SSR GSX21 02 AA and SSR GLX29 02 AA on page 113 SSR GSX31 02 on page 114 SSR GTX32 04 and SSR GTX32 0...

Page 118: ...ecial pinout RJ 45 Connector Pin Assignments X Pedition APHY 82V and X Pedition APHY 92V Pin Connection 1 Receive analog signal 2 Receive reference 3 Pin used for shield reference if you use a shielde...

Page 119: ...for Telnet connection from a host on the network The port is configured for Media Data Interface MDI You use this port to manage the X Pedition using CLI or SNMP Connector Pin Assignments The connect...

Page 120: ...256 108 Enterasys X Pedition 8000 8600 Getting Started Guide Table 24 10 100 Ethernet Management Port Pin Assignments Pin Connection 1 TX Diff Output 2 TX Diff Output 3 RX Diff Output 4 Unused 5 Unuse...

Page 121: ...er Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 Multimode Fiber 62 5 125 2 km 1 24 mi SC Single Mode Fiber 10 125 30 km 18 64 mi SC Table 26 SSR FDDI 02 Receiver Transmitter Receiver Sensitivity Transmit...

Page 122: ...it or receive see SSR GLX39 02 on page 110 for attaching cables 62 5 micron or 50 micron multimode fiber optic cable 9 5 micron single mode fiber optic cable Maximum 550 meters 1804 feet 1 segment len...

Page 123: ...m 7 1805 ft SC 10 125 m SMF N A 2 5000 m 7 16404 ft SC Table 32 SSR GSX31 04 1000BASE SX Multimode Fiber Specifications Fiber Diameter Modal Bandwidth Range Connector 62 5 125 m 160 MHz km 2 220 m 7...

Page 124: ...it or receive see SSR GLX39 02 on page 110 for attaching cables 9 5 micron single mode fiber optic cable Maximum 70 kilometers 229 659 feet segment length for 10 micron SMF fiber optic cable Minimum c...

Page 125: ...e the use of a fiber crossover cable Tx Table 38 SSR GLX39 02 Media Specifications Port Type Specification 1000BASE LX 802 3z standard also uses 802 3x for flow control SC style Media Interface Connec...

Page 126: ...s the media specifications for the SSR GSX31 02 T Series line card Optics Table 39 SSR GSX31 02 Media Specifications Port Type Specification 1000BASE SX 802 3z standard also uses 802 3x for flow contr...

Page 127: ...and SSR GTX32 02 connectors Figure 37 SSR GTX32 04 and SSR GTX32 02 RJ 45 connectors Table 41 SSR GTX32 04 and SSR GTX32 02 Recommended Cable Types and Specifications Cable Type Max Length Connector 1...

Page 128: ...onnected to the receive port on the other device The receive port on the X Pedition should be connected to the transmit port on the other device Cabling and Connector Specifications The following tabl...

Page 129: ...WAN line card to CSU DSU data port 1 1 Connector cables for WAN line cards may be ordered from Enterasys Networks For detailed information including part numbers see SSR HSSI 02 CK on page 117 50 pin...

Page 130: ...or Figure 38 50 pin HSSI connector The Enterasys SSR HSSI 02 CK line card uses standard copper twisted pair cable with identical 50 pin HSSI connectors at each end to attach to a CSU DSU module To att...

Page 131: ...the appropriate bandwidth The following table lists the pin assignments for the RJ 45 connector on the SSR HTX22 08 AA and SSR HTX12 08 AA and for the RJ 45 connector on the switch router or host on...

Page 132: ...ure 39 SSR HTX22 08 AA and SSR HTX12 08 AA RJ 45 connectors 2 Plug one end of the cable into the line card and the other end into the hardware at the other end of the connection TXD transmit data 6 RX...

Page 133: ...ns Port Type Specification 10BASE T 802 3 standard RJ 45 connector wired as Media Data Interface Crossed MDIX see Figure 39 for pin assignments EIA Category 3 4 or 5 unshielded twisted pair cabling Ma...

Page 134: ...e 49 SSR POS29 04 and SSR POS21 04 Recommended Cable Types and Specifications Cable Type Max Length Connector 1300 nm MMF 62 5 125 um 2 000 m 1 24 mi MT RJ 1300 nm SMF 9 125 um 15 000 m 9 32 mi MT RJ...

Page 135: ...e 51 SSR SERCE 04 AA and SSR SERC 04 AA Media Specifications Port Type Specification Dual serial V 35 X 21 EIA530 EIA530A or RS449 LFH 60 high density connector see LFH 60 high density connector on pa...

Page 136: ...ce you wish to use 2 Plug the remote end of the connector for each port you wish to use into its respective CSU DSU data port Table 53 SSR SERCE 04 AA and SSR SERC 04 AA Connector Pin Assignments Pin...

Page 137: ...ve the problem e g changing mode switches rebooting the unit etc The serial and revision numbers of all involved Enterasys Networks products in the network A description of your network environment la...

Page 138: ...Help 126 Enterasys X Pedition 8000 8600 Getting Started Guide The device history i e have you returned the device before is this a recurring problem etc Any previous Return Material Authorization RMA...

Page 139: ...5 C chassis 10 installation 56 powering on 86 CLI 9 CLI port 15 cable installation 107 Command Line Interface 9 access modes Configure mode 87 Enable mode 87 User mode 87 configuration file 98 Configu...

Page 140: ...notes 71 M management cables installation 107 management platforms 9 memory PCMCIA flash card 15 messages SYSLOG 95 MIBs 9 N networking layers 3 NVRAM 14 O OC 12 48 OC 3 46 OSPF 7 overview 1 hardware...

Page 141: ...SSR GSX21 02 AA 35 113 SSR GSX31 02 37 114 SSR GSX31 04 30 111 SSR GTX32 02 39 115 SSR GTX32 04 39 115 SSR HFX21 08 AA 41 116 SSR HFX29 08 AA 41 116 SSR HSSI 02 CK 42 117 SSR HTX12 08 AA 44 119 SSR HT...

Page 142: ...Index 130 Enterasys X Pedition 8000 8600 Getting Started Guide...

Reviews: