Installing the Hardware
66
Enterasys X-Pedition 8000/8600 Getting Started Guide
Firmware Image Requirements
Version 8.2.0.0 or later.
Default Module Settings
The CM4 comes with the baud rate on RS232 console port set to 9600.
Preparing the Module
•
You must install the PCMCIA card before you install the command module. You cannot add or
remove a PCMCIA card while the unit is powered on.
Installing a Memory Upgrade
1.
Determine how much memory is already installed on the Control Module. If you do not
know how much memory is installed on the Control Module, enter the system show hardware
command in Enable mode. The amount of memory is reported as the System Memory size. For
example:
2.
Power down the chassis.
Note:
If the X-Pedition chassis contains a redundant Control Module, you do not need to power
down the X-Pedition. You must, however, press the Hot Swap button before removing the
Control Module.
CAUTION: Before performing any upgrade or installation, ensure that you are properly
“grounded” to avoid electrostatic discharge. The switch must be powered off before
installing or replacing any module.
xp# system show hardware
Hardware Information:
System type:
X-Pedition 8600, Rev. A
CPU Module type:
CPU-Elan, Rev. 0
Processor:
R5000, Rev 3.0, 249.99 MHz
Icache size:
32 Kbytes, 32 bytes/line
Dcache size:
32 Kbytes, 32 bytes/line
CPU Board Frequency:
83.33 MHz
Switching Fabrics:
2 (Active = Fabric 1)
PCMCIA card:
No card present
System Memory size:
64 MBytes
Network Memory size:
8 MBytes
MAC Addresses
System: 00e063:fdd700
10BASE-T CPU Port:00e063:fdd701
Internal Use:
00e063:fdd702 -> 00e063:fdd73f
CPU Mode:
Active
Redundant CPU:
Not present
Summary of Contents for 8000/8600
Page 1: ...Getting Started Guide Revision Date 11 27 2002 8000 8600 9032552 16...
Page 8: ...vi Enterasys X Pedition 8000 8600 Getting Started Guide...
Page 116: ...104 Enterasys X Pedition 8000 8600 Getting Started Guide...
Page 142: ...Index 130 Enterasys X Pedition 8000 8600 Getting Started Guide...