4. Using a #2 Phillips screwdriver, remove 9 machine screws
F
that secure the AC board in place.
See Figure 45.
5. Carefully remove the AC board. Avoid gripping the board by the large chokes (coils). If necessary, the
plastic relay housings such as
G
can be used to hold the board.
Figure 45 Dismounting AC Board
6. Replace the AC board. Perform all previous steps in reverse order.
Carefully insert the AC board. Ensure that the board fits over the two alignment pins
H
. Components
on the board can be damaged through mishandling at this stage.
Replace the screws
F
.
Replace the connectors
E
and
D
. See Figure 44
if necessary.
Replace the transformer wires
C
. Make certain to observe the correct wire positions. See Figure 43
if necessary. Make certain that the wires are fully inserted and that no stray strands are exposed.
After latching, tug on the wires to ensure that they are secure.
Replace the AC wires
B
and the RP-SMA cable
A
. See Figure 42
if necessary. After latching, tug on
the wires to ensure that they are secure.
Replacement is complete.
F
F
F
F
F
F
F
F
F
G
H
H
Summary of Contents for OutBack POWER Mojave OGHI8048A
Page 1: ...Mojave Grid Hybrid Inverter Charger OGHI8048A Operator s Manual...
Page 30: ...30 900 00275 01 001 Rev A 2021 OutBack Power All Rights Reserved User Interface NOTES...
Page 48: ...48 900 00275 01 001 Rev A 2021 OutBack Power All Rights Reserved Operation NOTES...
Page 110: ...110 900 00275 01 001 Rev A 2021 OutBack Power All Rights Reserved Specifications NOTES...
Page 115: ...900 00275 01 001 Rev A 115 Index This page intentionally left blank...