38
ESE 904 - 1304 DBG DIN
Status: at
January 2013
4.5 Switching the generator off
Proceed as follows to shut down the generator.
WARNING!
Hot parts can ignite flammable and explosive materials.
•
Avoid flammable materials at the operating site.
•
Avoid explosive materials at the operating site.
•
Allow the generator to cool down.
The device is switched off as follows:
1. Switch off or disconnect devices.
2. Continue to run the engine for about two minutes.
3. Turn the START-STOP switch to "0" position
(Fig. 4-2-(1))
until the engine stops.
4. Set the fuel cock to "closed“
(Fig. 5-10-(1))
as necessary.
5. Allow the device to cool down
The generator is switched off.
WARNING!
In an emergency, the generator can be stopped by
pressing the emergency -OFF switch
(Fig. 4-2-(1))
. The
button is turned to the left or the right to restart the ag-
gregate until the locking is removed again.
We request that you only switch off the device using the
EMERGENCY-STOP switch in an emergency. Switch off
using the EMERGENCY-STOP switch only interrupts the
ignition so it is still possible for fuel to ignite in the si-
lencer due to residual amounts of fuel in the carburettor.
4.6 Connecting up consumers/appliances
Proceed as follows to connect appliances to the generator.
Switching the device off
Note
Summary of Contents for ESE 1104 DBG ES FS DIN
Page 10: ...General information 10 ESE 904 1304 DBG DIN Status at January 2013 Notes...
Page 24: ...24 ESE 904 1304 DBG DIN Status at January 2013 Notes...
Page 31: ...Status at January 2013 ESE 904 1304 DBG DIN 31 Notes...
Page 47: ...Status at January 2013 ESE 904 1304 DBG DIN 47 Notes...
Page 75: ...Status at January 2013 ESE 904 1304 DBG DIN 75 Notes...
Page 79: ...Status at January 2013 ESE 904 1304 DBG DIN 79 Notes...