530001-00 Use this option to select your product group. The user-
defined option allows the correction of any medium using
density or temperature measurement or the calculation of
the mass using a density sensor. The mineral oil options
initiate volume correction based on temperature and
another, optional density sensor.
The result is
530008-00 Select volume here to initiate volume correction. A tem-
perature or a density sensor is required for this purpose. If
you select mass here, the measured volume is converted
to mass using a required density sensor.
Mass unit
530009-00 Use this option to specify the required mass unit, into
which the volume should be converted. The counter value
then appears on the display and in the analyses in this
mass unit. The preset counter must also be entered in this
unit.
Density unit
530002-00 Use this option to select your preferred density unit, in
which the subsequent values must be entered.
Operating density
530003-00 Select "measured" if you wish to use a density sensor for
measurement. If you calculate the density internally, you
only require a temperature sensor and can select "calcu-
lated".
Reference condition
530004-00 Use this option to select the required reference operating
condition for volume correction.
Reference density
530005-00 Use this option to enter the density of the medium under
the reference operating conditions selected previously.
Pressure unit
530007-00 Use this option to select your preferred pressure unit, in
which the subsequent values must be entered.
Pressure
530006-00 Use this option to enter the pressure, at which the
medium flow is measured. This value is also taken into
account when calculating volume correction. It is suffi-
cient to enter a relative pressure value of 0 to switch off
compensation based on the pressure value.
Expansion coeff. unit
530011-00
Expansion coeff.
530010-00 The thermal expansion coefficient describes the expansion
of a medium at a temperature change of 1°C/°F starting
from the temperature set in the reference condition.
Batch printout
All of the relevant parameters to print out a batch report
can be defined here.
Printout
510200-00 Use this option to activate printing. You can also choose
whether printing can be initiated manually on-site, or
whether a printout should also take place at the end of
every batch.
Baudrate
510214-00 Set the transmission rate for communication.
Number of copies
510201-00 Use this option to set the required number (0-5) of auto-
matic printouts.
Characters/line
510212-00 Use this option to specify the maximum number of charac-
ters per line.
Number of headers
510202-00 Use this option to specify the number (0-5) of required
lines for user-defined text at the beginning of the batch
report.
Header x
510203-00
…06-00
Use this option to enter the user-defined text for printing
on the batch report.
Number of footers
510207-00 Use this option to enter the number of lines for user-
defined text at the end of the batch report.
Footer x
510208-00
…11-00
Use this option to enter the user-defined text for printing
on the batch report.