Appendix
190
13.1.7
Constricted rectangular weirs
L00-FMU90xxx-05-00-00-xx-009
!
Note!
In the "width" parameter, the width of the weir can be adjusted. The corresponding change of the
flow curve is automatically performed by the Prosonic S.
!
Note!
After selecting the type of weir, Q
max
can be adjusted to the flow conditions. Q
max
defines the flow
at which the output current is 20 mA.
Type of weir
B [mm]
H
max
[mm]
Q
max
[m
3
/h]
RectWThr 2H
200
120
51,18
RectWThr 3H
300
150
108,4
RectWThr 4H
400
240
289,5
RectWThr 5H
500
270
434,6
RectWThr 6H
600
300
613,3
RectWThr 8H
800
450
1493
RectWThr T0
1000
600
2861
RectWThr T5
1500
725
6061
RectWThr 2T
2000
1013
13352
k
k
45°
BD
≥
3 H
max
≥
2 H
max
H
max
B
≥
2 H
max
k
3 mm
≈