Proline Prowirl 72
12 Factory settings
E Hauser
105
12
Factory settings
12.1
Metric system units (not for USA and Canada)
Length, temperature units (see Page 75 ff.)
Language (see Page 78)
100% value line 1 and line 2 (see Page 80)
The factory settings in the table are given in the unit dm³/s. If another unit is selected in the UNIT
FLOW function (see Page 74), the corresponding value is converted and displayed in the selected
unit.
Totalizer unit (see Page 82)
Unit
Length
mm
Temperature
°C
Country
Language
Country
Language
Australia
English
Norway
Norsk
Belgium
English
Austria
Deutsch
Denmark
English
Poland
Polski
Germany
Deutsch
Portugal
Portugues
England
English
Sweden
Svenska
Finland
Suomi
Switzerland
Deutsch
France
Francais
Singapore
English
The Netherlands
Nederlands
Spain
Espanol
Hong Kong
English
South Africa
English
India
English
Thailand
English
Italy
Italiano
Czechia
Ceski
Luxembourg
Francais
Hungary
English
Malaysia
English
Other countries
English
Nominal diameter
DN
Flange
Wafer
DIN
[mm]
ANSI
[inch]
Gas
[dm³/s]
Liquid
[dm³/s]
Gas
[dm³/s]
Liquid
[dm³/s]
15
½"
7.2
1.4
8
2
25
1"
32
4
48
6
40
1½"
80
10
80
16
50
2"
160
16
160
20
80
3"
320
40
400
48
100
4"
560
64
640
80
150
6"
1280
160
1600
160
200
8"
2400
320
–
–
250
10"
4000
480
–
–
300
12"
5600
640
–
–
Flow
Unit
Volume flow
m³
Calculated mass flow
kg
Corrected volume flow
Nm³
Summary of Contents for Proline Prowirl 72
Page 4: ...QUICK SETUP for quick commissioning Proline Prowirl 72 4 Endress Hauser...
Page 20: ...3 Installation Proline Prowirl 72 20 Endress Hauser...
Page 42: ...6 Commissioning Proline Prowirl 72 42 Endress Hauser...
Page 44: ...7 Maintenance Proline Prowirl 72 44 Endress Hauser...
Page 114: ...www endress com worldwide BA084D 06 en 12 05 71008404 FM SGML 6 0...