Micropilot NMR84
Operating menu
Hauser
169
Assign TV
Navigation
Setup → Advanced setup → Communication → HART output → Configuration
→ Assign TV
Description
Assign a measured variable to the tertiary dynamic variable (TV).
Selection
• None
• Tank level
• Tank ullage
• Measured level
• Distance
• Displacer position
• Water level
• Upper interface level
• Lower interface level
• Bottom level
• Tank reference height
• Liquid temperature
• Vapor temperature
• Air temperature
• Observed density value
• Average profile density
• Upper density
• Middle density
• Lower density
• P1 (bottom)
• P2 (middle)
• P3 (top)
• GP 1 value
• GP 2 value
• GP 3 value
• GP 4 value
Factory setting
Water level
Additional information
Read access
Operator
Write access
Maintenance
The
Measured level
option doesn't contain a unit. If a unit is needed, select the
Tank
level
option.
Tertiary variable (TV)
Navigation
Setup → Advanced setup → Communication → HART output → Configuration
→ Tertiary var(TV)
Prerequisite
≠
None
Description
Shows the value of the third HART variable (TV).