Operating menu
Micropilot NMR84
192
Hauser
Deformation factor
Navigation
Setup → Advanced setup → Application → Tank calculation → HyTD → Deform factor
Description
Defines the deformation factor for the HyTD (change of device position per change of
level).
User entry
–1.0 to 1.0 %
Factory setting
0.2 %
Additional information
Read access
Operator
Write access
Maintenance