Micropilot NMR84
Operating menu
Hauser
165
Selection
• AIO B1-3
• AIO C1-3
• Custom
Factory setting
Custom
Additional information
Read access
Maintenance
Write access
Maintenance
Assign PV
Navigation
Setup → Advanced setup → Communication → HART output → Configuration
→ Assign PV
Prerequisite
Custom
Description
Assign a measured variable to the primary dynamic variable (PV).
Additional information:
The assigned measured variable is also used by the current output.
Selection
• None
• Tank level
• Tank ullage
• Measured level
• Distance
• Displacer position
• Water level
• Upper interface level
• Lower interface level
• Bottom level
• Tank reference height
• Liquid temperature
• Vapor temperature
• Air temperature
• Observed density value
• Average profile density
• Upper density
• Middle density
• Lower density
• P1 (bottom)
• P2 (middle)
• P3 (top)
• GP 1 value
• GP 2 value
• GP 3 value
• GP 4 value
Factory setting
Tank level
*
Visibility depends on order options or device settings