Installation
Micropilot NMR84
14
Hauser
D1
D2
L
100 mm (4 in)
150 mm (6 in)
300 mm (12 in)
150 mm (6 in)
200 mm (8 in)
300 mm (12 in)
200 mm (8 in)
250 mm (10 in)
300 mm (12 in)
250 mm (10 in)
300 mm (12 in)
450 mm (18 in)
1)
= antenna size
5.2
Post-installation check
m
Is the device undamaged (visual inspection)?
m
Does the device conform to the measuring point specifications?
For example:
• Process temperature
• Process pressure (refer to the chapter on "Material load curves" of the "Technical Information"
document)
• Ambient temperature range
• Measuring range
m
Are the measuring point identification and labeling correct (visual inspection)?
m
Is the device adequately protected from precipitation and direct sunlight?