EM TEST
UCS 500 Series
Operating Manual
V 5.40
39 / 99
Surge
Coupling/decoupling network as per IEC 61000-4-5 for signal lines
type CNV 504/508 (4 wires and 8 wires)
3 phase CNV 503 up to 100A
TSurge module
TSurge 7
Power Fail
V4780 transformer with taps
–
Transformer with taps at 40%&, 70%, 80%
- 230V / 16A
.
MV 2616 Variac
– Motorvariac 0-260V / 16 or 32A
– Control signal 0-10V dc.
Magnetic field
MS 100
Magnetic field antenna
MC 2630
Current transformer up to 30A/m
MC 26100
Current transformer up to 1000A/m
MC2630
MC26100
General for Burst and Surge
CNI 503 external coupling/decoupling network
-
EUT mains supply 400 V rms max. // 480V for USA
-
Nominal current
In = 16 A / 32A / 63A / 100 A rms
-
Frequency
50/60 Hz
-
Coupling to
all lines, N, PE
-
50
Burst output
The coupling will be controlled by the UCS 500 or EFT
500
-
Output for Surge
coupling to other coupling networks as CNV types ...
User software " iec.control "
- Test, analysis and documentation with windows
- License version for testing according the most automotive standards
- Report generator with export function to word-processing software
USB Interface
FER-USB
Ferrite for suppress burst pulses on the USB cable.
Application: 8 turns for the best result. max. 10cm above ground.
The included USB cable has integrated ferrites and is suitable for burst tests with
the UCS 500. Interferences usually occur on the computer side. With the ferrite-
FER USB Interference will be attenuated additionally on the USB cable.