EM TEST
UCS 500 Series
Operating Manual
V 5.40
28 / 99
6.5.
Telecom Surge Generator as per IEC 61000-4-5 (TSurge module)
UCS 500N5T
(includes TSurge module)
TSurge7 (external)
As per ITU and ETS recommendations
Output voltage open circuit
160V
– 5’000V
10%
250V
– 7’000V
10%
Pulse 10/700
s
Front time T
F
(rise time tr)
10
s
30% (1.0
s
30%)
Pulse duration td
700
s
20%
As per FCC part 68 Pulse B
Output voltage open circuit
160V
– 5’000V
10%
250V
– 7’000V
10%
Front time T
F
9
s
30%
Pulse duration td
720
s
20%
Output current short circuit
4
– 100A
6
– 175A
Rise time tr
5
s
30%
Pulse duration td
320
s
20%
As per IEC 61000-4-5
Pulse 10/700
s
Open circuit output voltage
160V
– 5’000V
10%
250V
– 7’000V
10%
Rise time tr
10
s
30%
Pulse duration td
700
s
20%
Short circuit output current
4
– 100A
6
– 175A
Rise time tr
5
s
20%
Pulse duration td
320
s
20%
Coupling
As per ITU
For 2 wire T1 and T2 with 25
each
As per FCC part 68
For 2 wire T1 and T2 with 25
each
As per IEC 61000-4-5
For 4 wire T1,T2,T3,T4 with 100
each
External networks are required for other applications (options)
General
Energy storage capacitor
20
F
Polarity
Positive, negative or alternating
Counter select
1
– 30,000 or endless
Dimensions
Housing
19“, 3HU, 450x500x155mm (ext. TSurge6.1 module)
Weight
approx. 11.85kg
Accessories Included
HV cable set
Connect the TSurge module to UCS 500N7
Control cable
To control TSurge via UCS 500N7
EUT adapter
socket depends on the country of use