INSTALLATION (continued)
Flush Wall Installation
FRONT TRIM OR
NON-COMBUSTIBLE MATERIAL
(INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
24”
TO TOP OF CHASE
2 X 4
HEADER
FINISHED WALL
(COMBUSTIBLE)
FINISHED WALL
(NON-COMBUSTIBLE)
Note:
If interior of chase requires drywall per local code, 2 x 4 Header
must be reduced to 2 x 2.
Figure 32
NOTE: If the Interior of the chase is required by local code to
be dry walled the face wall above the fireplace must be built
with 2 x 2 lumber to meet clearances.
Figure 33
Combustible Surround Installation
24”
TO TOP OF CHASE
JOINT BETWEEN FINISHED WALL AND
UNIT SEALED WITH 300° F 149
MATERIAL (SEALANT IS OPTIONAL)
° C
SEALANT
COMBUSTIBLE SURROUND
MANTELSHELF
2 X 4
HEADER
FINISHED WALL
(COMBUSTIBLE)
FINISHED WALL
(NON-COMBUSTIBLE)
FRONT RIM OR NON-COMBUSTIBLE
MATERIAL (INSTALLATION IS OPTIONAL)
Figure 34
Attention:
Cold climate installation recommendation: When
installing this unit against a non-insulated exterior wall, it is
recommended that the outer walls be insulated to conform to
applicable insulation codes.
Vent Runs
In planning the installation for the fireplace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for
the appliance and the electrical wiring. (If the fan option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four corner supports. (Example: Four concrete masonry blocks.)
These supports must be positioned so they contact all four
perimeter edges on the bottom of the unit.