35919-4-1015
Page 20
INSTALLATION (continued)
VERTICAL, 90 DEGREE ELBOW WITH HORIZONTAL
TERMINATION
24”
TO TOP OF CHASE
“A”
DISTANCE
TO BOTTOM
OF UNIT
3” (76mm)
MINIMUM CLEARANCE
TO COMBUSTIBLES
VENT CAP/
THIMBLE
WALL FIRESTOP
12” Rise
Required
FINISHED WALL
(NON-COMBUSTIBLE)
FINISHED WALL
(COMBUSTIBLE)
9”
BOTTOM
OF FRAMING
A DIMENSION
(Dimensions in inches)
DVCP32
57-1/2
DVCP36
57-1/2
DVCP42
59-1/8
Figure 35
VERTICAL, 90 DEGREE ELBOW TO HORIZONTAL OUT THE
WALL (12-in minimum rise before elbow)
90° ELBOW
“A”
PIPE
LENGTH
VENT CAP
WALL FIRESTOP/
THIMBLE
“B”
“C”
A
B
C
(Dimensions in inches)
6
11-1/4 to 12-3/4
4-3/4 to 6-1/4
9
14-1/4 to 15-3/4
7-3/4 to 9-1/4
12
17-1/4 to 18-3/4
10-3/4 to 12-1/4
Figure 36
CORNER INSTALLATION - VERTICAL, 90 DEGREE ELBOW
TO HORIZONTAL OUT THE WALL(12-in minimum rise before
elbow)
WALL FIRESTOP/
THIMBLE
VENT
CAP
6” (152 mm)
MINIMUM
9” (229 mm)
MINIMUM
Dim.
DVCP32
DVCP36
DVCP42
(Dimensions in inches)
A
37-3/4
39-7/8
44-1/8
B
26-3/4
28-3/16
31-3/16
C
12-3/4
13-3/4
15-15/16
D
53-3/8
56-3/8
62-3/8
Figure 37