Note: Island and Room Divider installation is possible as long as the horizontal portion of the vent system does not exceed 20 feet with a
minimum vertical run of 8 feet. See details in Venting Section.
When you install your Direct Vent Fireplace in Room divider or Flat on wall corner positions, a minimum of 6 inches clearance must be
maintained from the perpendicular wall and the front edge of the appliance.
LOCATING FIREPLACE
CLEARANCES
Clearances
Clearance from bottom edge of fireplace to ceiling is 72-in
Clearance from side of fireplace to adjacent sidewall is 6-in.
Refer to framing dimensions on page 18.
Note: 72-in minimum applies when unit is installed in wall above
floor level.
72”
(183cm)
6” (152mm)
Figure 20
Television Considerations
Installing a television above an appliance has become increas-
ingly popular; however, the area above any appliance gets hot and
most TV manufacturers recommend against placing their products
near a heat source.
If you install a television above this appliance, Empire Comfort
Systems accepts no responsibility for damage or injuries. Follow
the television manufacturer’s installation instructions, including
any recommendations regarding proximity to heat sources.
If you have a TV above your appliance, turn off the appliance and
let it cool completely before servicing or touching any buttons on
the TV.