35919-4-1015
Page 6
SPECIFICATIONS
DVCP32NAT DVCP32LP DVCP36NAT DVCP36LP DVCP42NAT DVCP42LP
Input BTU/Hr Maximum
24,000
22,000
24,000
24,000
28,500
26,500
Input BTU/Hr Minimum (millivolt only)
18,000
18,000
18,000
19,000
21,000
22,000
KWH (Maximum)
7.03
6.45
7.03
7.03
8.35
7.77
KWH (Minimum)
5.27
5.27
5.28
5.57
6.15
6.3
Orifice
42
54
42
1.45mm
39
1.55mm
Air Shutter Opening
1/4-in
Full Open
1/4-in
Full Open
1/8-in
Full Open
Gas Inlet Shutoff Valve (Pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
1/2 NPT
NOTE:
Air shutter settings are factory minimum settings. Some venting configurations may require minor air shutter adjustments for
optimum performance.
GAS SUPPLY PRESSURES
GAS TYPE
MAXIMUM
MINIMUM
MANIFOLD
NAT
14.0-in
4.5-in
3.5-in
LP
14.0-in
10.8-in
10.0-in
Remote Control Options
& Accessories
Description
Models Used On
FRBC
Millivolt Battery Remote ON/OFF
DVCP(32,36,42)BP(3,7)
FRBTC
Millivolt Battery Remote Thermostat
DVCP(32,36,42)BP(3,7)
TMW
Millivolt Wireless Wall Thermostat
DVCP(32,36,42)BP(3,7)
TRW
Millivolt Reed Switch Wall Thermostat
DVCP(32,36,42)BP(3,7)
FWS-1
Direct Ignition/Millivolt Wall Switch
DVCP(32,36,42)BP(3,7)
FRBTP
Battery Operated Remote Control with Programmable Thermostat DVCP(32,36,42)BP(3,7)
RVKN-1
Remote Kit, NAT (Stepper Motor)
DVCP(32,36,42)BP7N
RVKP-1
Remote Kit, LP (Stepper Motor)
DVCP(32,36,42)BP7P
Venting Options
Description
DVVK-4TSP
Top vent kit (horizontal) - 4-½-in to 6-in (114.3 mm to 152 mm) wall thickness
DVVK-4TP
Top vent kit (horizontal) - 8-in to 12-in (203 mm to 305 mm) wall thickness
DVVK-4VP
Vertical vent kit
DVVK-4F
Horizontal flex vent kit (4-ft FLEX)
SD46DVA-FCFX7 Flex Adaptor Collar (must be used with flex kits)
Conversion Kits
Description
Used On
31768
Conversion Kit, DV (Natural to Propane)
DVCP32BP30
31769
Conversion Kit, DV (Propane to Natural)
DVCP302BP30
31770
Conversion Kit, DV (Natural to Propane)
DVCP306BP30
31771
Conversion Kit, DV (Propane to Natural)
DVCP306BP30
31772
Conversion Kit, DV (Natural to Propane)
DVCP42BP30
31773
Conversion Kit, DV (Propane to Natural)
DVCP42BP30
32874
Conversion Kit, DV (Natural to Propane)
DVCP702BP70
32875
Conversion Kit, DV (Propane to Natural)
DVCP702BP70
32876
Conversion Kit, DV (Natural to Propane)
DVCP706BP70
32877
Conversion Kit, DV (Propane to Natural)
DVCP706BP70
32878
Conversion Kit, DV (Natural to Propane)
DVCP42BP70
32879
Conversion Kit, DV (Propane to Natural)
DVCP42BP70