Product Certifications
79
Product Certifications
January 2017
Reference Manual
00809-0100-4853, Rev AB
Appendix B
Product Certifications
Rev 1.19
European Directive Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 79
Ordinary Location Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 79
Installing Equipment in North America . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 79
Installation drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 87
B.1 European Directive
Information
A copy of the EU Declaration of Conformity can be found at
the end of the Quick Start Guide. The most recent revision
of the EU Declaration of Conformity can be found at
B.2 Ordinary Location
Certification
As standard, the transmitter has been examined and tested
to determine that the design meets the basic electrical,
mechanical, and fire protection requirements by a
nationally recognized test laboratory (NRTL) as accredited
by the Federal Occupational Safety and Health
Administration (OSHA).
B.3 Installing Equipment in
North America
The US National Electrical Code
®
(NEC) and the Canadian
Electrical Code (CEC) permit the use of Division marked
equipment in Zones and Zone marked equipment in
Divisions. The markings must be suitable for the area
classification, gas, and temperature class. This information
is clearly defined in the respective codes.
USA
E5
US Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: FM16US0089X
Standards: FM Class 3600 – 2011,
FM Class 3615 – 2006,
FM Class 3616 – 2011,
FM Class 3810 – 2005,
ANSI/NEMA
®
250 – 2003
Markings: XP CL I, DIV 1, GP B, C, D; T5;
DIP CL II, DIV 1, GP E, F, G; CL III;
T5(–50 °C
≤
T
a
≤
+85 °C);
Factory Sealed; Type 4X
I5
US Intrinsically Safe (IS) and Nonincendive (NI)
Certificate: FM16US0233
Standards: FM Class 3600 –2011,
FM Class 3610 – 2007,
FM Class 3611 – 2004,
FM Class 3616 – 2006,
FM Class 3810 – 2005,
NEMA 250 – 1991
Markings:
IS CL I, DIV 1, GP A, B, C, D;
CL II, DIV 1, GP E, F, G; Class III;
Class 1, Zone 0 AEx ia IIC T4;
NI CL 1, DIV 2, GP A, B, C, D;
T4(–50 °C
≤
T
a
≤
+70 °C); when connected
per Rosemount drawing 03151-1206;
Type 4X
Note
Transmitters marked with NI CL 1, DIV 2 can be installed in Division
2 locations using general Division 2 wiring methods or
Nonincendive Field Wiring (NIFW). See drawing 03151-1206.
Summary of Contents for Rosemount MultiVariable 3051SMV
Page 2: ......
Page 6: ...vi Reference Manual 00809 0100 4853 Rev AB Contents January 2017 Contents ...
Page 44: ...36 Reference Manual 00809 0100 4853 Rev AB Installation January 2017 Installation ...
Page 62: ...54 Reference Manual 00809 0100 4853 Rev AB Troubleshooting January 2017 Troubleshooting ...
Page 111: ......