Specifications and Reference Data
77
Specifications and Reference Data
January 2017
Reference Manual
00809-0100-4853, Rev AB
RTD input with 24 ft. (7,32 m) of ATEX/IEXCEx flameproof cable
03151-9066-0124
RTD input with 75 ft. (22,86 m) of ATEX/IEXCEx flameproof cable
03151-9066-0175
AL housing with M20
⫻
1.5 conduit- kit includes cable and cable glands
RTD input with 34-in. (86 cm) of shielded cable
03151-9064-0002
RTD input with 12 ft. (3,66 m) of shielded cable
03151-9064-0012
RTD input with 24 ft. (7,32 m) of shielded cable
03151-9064-0024
RTD input with 75 ft. (22,86 m) of shielded cable
03151-9064-0075
RTD input with 27-in. (69 cm) of armored cable
03151-9065-0202
RTD input with 4 ft. (1,22 m) of armored cable
03151-9065-0204
RTD input with 12 ft. (3,66 m) of armored cable
03151-9065-0212
RTD input with 24 ft. (7,32 m) of armored cable
03151-9065-0224
RTD input with 75 ft. (22,86 m) of armored cable
03151-9065-0275
RTD input with 25-in. (64 cm) of ATEX/IEXCEx flameproof cable
03151-9066-0202
RTD input with 12 ft. (3,66 m) of ATEX/IEXCEx flameproof cable
03151-9066-0212
RTD input with 24 ft. (7,32 m) of ATEX/IEXCEx flameproof cable
03151-9066-0224
RTD input with 75 ft. (22,86 m) of ATEX/IEXCEx flameproof cable
03151-9066-0275
SST housing with M20
⫻
1.5 conduit- kit includes cable and cable glands
RTD input with 34-in. (86 cm) of shielded cable
03151-9064-0002
RTD input with 12 ft. (3,66 m) of shielded cable
03151-9064-0012
RTD input with 24 ft. (7,32 m) of shielded cable
03151-9064-0024
RTD input with 75 ft. (22,86 m) of shielded cable
03151-9064-0075
RTD input with 27-in. (69 cm) of armored cable
03151-9065-0302
RTD input with 4 ft. (1,22 m) of armored cable
03151-9065-0304
RTD input with 12 ft. (3,66 m) of armored cable
03151-9065-0312
RTD input with 24 ft. (7,32 m) of armored cable
03151-9065-0324
RTD input with 75 ft. (22,86 m) of armored cable
03151-9065-0375
RTD input with 25-in. (64 cm) of ATEX/IEXCEx flameproof cable
03151-9066-0302
RTD input with 12 ft. (3,66 m) of ATEX/IEXCEx flameproof cable
03151-9066-0312
RTD input with 24 ft. (7,32 m) of ATEX/IEXCEx flameproof cable
03151-9066-0324
RTD input with 75 ft. (22,86 m) of ATEX/IEXCEx flameproof cable
03151-9066-0375
AL housing with G
1
/
2
conduit- kit includes cable and cable glands
RTD input with 34-in. (86 cm) of shielded cable
03151-9064-0002
RTD input with 12 ft. (3,66 m) of shielded cable
03151-9064-0012
RTD input with 24 ft. (7,32 m) of shielded cable
03151-9064-0024
RTD input with 75 ft. (22,86 m) of shielded cable
03151-9064-0075
RTD input with 27-in. (69 cm) of armored cable
03151-9065-0402
RTD input with 4 ft. (1,22 m) of armored cable
03151-9065-0404
RTD input with 12 ft. (3,66 m) of armored cable
03151-9065-0412
RTD input with 24 ft. (7,32 m) of armored cable
03151-9065-0424
RTD input with 75 ft. (22,86 m) of armored cable
03151-9065-0475
RTD input with 25-in. (64 cm) of ATEX/IEXCEx flameproof cable
03151-9066-0402
RTD input with 12 ft. (3,66 m) of ATEX/IEXCEx flameproof cable
03151-9066-0412
RTD input with 24 ft. (7,32 m) of ATEX/IEXCEx flameproof cable
03151-9066-0424
RTD input with 75 ft. (22,86 m) of ATEX/IEXCEx flameproof cable
03151-9066-0475
Summary of Contents for Rosemount MultiVariable 3051SMV
Page 2: ......
Page 6: ...vi Reference Manual 00809 0100 4853 Rev AB Contents January 2017 Contents ...
Page 44: ...36 Reference Manual 00809 0100 4853 Rev AB Installation January 2017 Installation ...
Page 62: ...54 Reference Manual 00809 0100 4853 Rev AB Troubleshooting January 2017 Troubleshooting ...
Page 111: ......