![Emerson PCM-22 Manual Download Page 93](http://html.mh-extra.com/html/emerson/pcm-22/pcm-22_manual_2400781093.webp)
Tips and Troubleshooting
P/N 400274-01 Revision A7
85
Missing Sensor Issues
Symptoms
One or more of the following symptoms would be observed:
1.
The
Master Sensor Missing
output function 25 is active.
2.
The
Follower Sensor Missing
output function 26 is active.
3.
The
Cycle Error
output function 66 is active. and the
CQ
serial
command returns 0x810 or 0x820.
4.
Several
ML1-8
values are the same and that value is the
Master
Length Upper Limit
in sync. steps.
5.
Several
FL1-8
values are the same and that value is the
Follower
Length Upper Limit
in resolver steps.
6.
Follower cycles occur with no products or between products.
7.
Products are being skipped (i.e., no Follower cycle occurs).
Possible Causes
1)
Check the functionality of the sensor using
IO0 (IO zero)
serial
command. It returns a hexadecimal mask of the active inputs.
2)
Electrical noise can be picked up on the sensor leads and cause false
triggering.
Follower Axis
1)
Make sure you are getting the Follower sensor input when you
are supposed to by widening the
Follower Sensor Valid Zone
.
This can be checked by querying serial command
IO0
(IO zero)
while monitoring the position of the Follower axis and the
Follower Sensor Missing
output function.
2)
Make sure that the
Follower Length Upper Limit
is within the
Follower Sensor Valid Zone
is close to the tolerances of the
application.
Master Axis
1)
Make sure you are getting the Master sensor input when you are
supposed to by widening the
Master Sensor Valid Zone
. This can
be checked by querying serial command
IO0
(IO zero)
while
monitoring the position of the Master axis and the
Master Sensor
Missing
output function.
2)
Make sure that the
Master Length Upper Limit
is within the
Master Sensor Valid Zone
is close to the tolerances of the
application.
See the
CQ
serial command
,
Follower Cycles
and
Master Cycles
screens.