PCM-22 Software Setup
P/N 400274-01 Revision A7
57
•
If the
Cycle Drop Out
input function is active, then the
Cycle Exit
input function is activated, and the
Cycle Drop Out
input function is
deactivated, then the Follower will exit the cycle at the end of the
current
Working Segment
. If the Follower is past the end of the
current
Working Segment
and is decelerating when the
Cycle Drop
Out
input function is deactivated, then the
Cycle Drop Out
input
function will not complete and it will exit at the end of the next
Working Segment
.
118
Working Ratio Increment
This edge triggered input is used to increment the
Working Ratio
by the
Working Ratio Change Increment
value. It is only functional when in a
cycle. It must be assigned using the
IF
serial command. It is uploaded
and downloaded by PCX. See the
TC5
serial command.
119
Working Ratio Decrement
This edge triggered input is used to decrement the
Working Ratio
by the
Working Ratio Change Increment
value. It is only functional when in a
cycle. It must be assigned using the
IF
serial command. It is uploaded
and downloaded by PCX. See the
TC5
serial command.
Typical Input Assignments
The following input assignments handle most customer needs.
Input
Function
Notes
1
45-Zero Master Cycle
Active at all times, if the Master
is defined by sensor.
2
15-Home Sensor (0)
46-Zero Follower Cycle
Only active outside of a cycle or
index.
Only active in a cycle.
3
11-Stop Motion
21-Reset Fault
Active at all times.
Only active when faulted.
4
29-Initiate Program
Only active outside of a program.
5
1-Home (0) Initiate
116-Cycle Exit
Only active outside of a program.
Only active in a cycle.
6
49-Cycle Drop Out
Only active in a cycle.
7
72-Master Phase Increment
Only active in a cycle.
8
73-Master Phase Decrement
Only active in a cycle.
13
115-Reset Master
Only active outside of a cycle.