Internal component tools
Use the following tools for turbine meter disassembly:
•
Needle nose pliers
•
Torque wrench (dependant on size)
•
Ratchet with correspondent hex socket (dependant on size), or screwdriver with
hexagonal tip
•
3 mm Allen key
•
3.5 mm flathead screwdriver
•
Mallet
9.3
Prepare for mechanical disassembly
Protect the rotor blades from rough handling. Blade position is critical to turbine meter
performance. Before removing the turbine meter from the system, consider the following
precautions.
Prerequisites
WARNING!
EQUIPMENT HANDLING AND OPERATING HAZARD
Wear personal protective equipment appropriate to the situation when working with the
turbine meter. Adhere to all safety standards and best practices for operating the equipment.
Failure to comply may result in death or serious injury.
WARNING!
PRESSURE HAZARD
The turbine meter is subject to pressurized fluids. Depressurize the turbine meter before
disassembly.
Failure to comply may cause high pressure fluids to leak, resulting in death or serious injury.
WARNING!
VOLTAGE HAZARD
Disconnect equipment from power before opening the LME and/or RME. Do not open them
while power is on and an explosive gas atmosphere is present.
Failure to comply may result in death or serious injury.
Procedure
1.
Disconnect all power to the turbine meter and vent all line pressure.
Planned maintenance
72
Daniel Series 1500 Liquid Turbine Meter, NPS 3-24
Summary of Contents for daniel 1500 series
Page 8: ......
Page 12: ...Plan 2 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 64: ...Prepare the turbine meter for use 54 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 66: ...Install 56 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 72: ...Installation procedure 62 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 74: ...Testing 64 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 75: ...Part III Operate Operate User manual 65 ...
Page 76: ...Operate 66 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 80: ...Maintain 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 101: ...Decommission the turbine meter User manual 91 ...
Page 102: ...Decommission the turbine meter 92 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 103: ...Decommission the turbine meter User manual 93 ...