9.5
Electronics enclosure disassembly
WARNING!
ELECTRONIC HAZARD
Power off the electronics after every use.
Servicing the turbine meter while powered may result in death or serious injury.
Important
Do not use a hammer to assemble the housing.
9.5.1
Disassemble the LME/RME - Standard enclosure
1.
Uninstall the security seal wire.
2.
Uninstall the security wire.
3.
Uninstall the security latch.
4.
Uninstall the solid end cap.
5.
Uninstall the wiring connections from the preamplifier.
6.
Loosen and remove the socket screws from the plate bracket to the housing.
7.
Loosen and remove the preamplifier socket screw to the bracket plate.
8.
Loosen the grounding lugs and remove the cable.
9.
Uninstall the conduit.
10.
For LME only - Remove the anti-rotation bracket and pickoffs.
11.
Uninstall the four socket head screws placed at the bottom of the housing.
12.
Remove the housing from the flameproof pad.
13.
Uninstall the O-ring from the pad.
9.5.2
Disassemble the LME - High temperature enclosure
1.
Uninstall the security seal wire.
2.
Uninstall the security latch.
3.
Uninstall the solid end cap.
4.
Uninstall the wiring connections from the terminal block.
5.
Loosen and remove the socket screws from the plate to the housing.
6.
Loosen and remove the socket screws from the bracket plate.
7.
Loosen the grounding lugs and remove cable.
8.
Uninstall the conduit.
9.
Remove the anti-rotation bracket and the pickoffs.
10.
Uninstall the four socket screws placed at the bottom of the housing.
Planned maintenance
User manual
81
Summary of Contents for daniel 1500 series
Page 8: ......
Page 12: ...Plan 2 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 64: ...Prepare the turbine meter for use 54 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 66: ...Install 56 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 72: ...Installation procedure 62 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 74: ...Testing 64 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 75: ...Part III Operate Operate User manual 65 ...
Page 76: ...Operate 66 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 80: ...Maintain 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 101: ...Decommission the turbine meter User manual 91 ...
Page 102: ...Decommission the turbine meter 92 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 103: ...Decommission the turbine meter User manual 93 ...