Accessory hookup
It is important that the correct service manual be referenced before attempting to use
accessories or instrumentation with the Series 1500 LTM. Contact the factory or nearest
Daniel Measurement and Control Sales and Service Office if service manuals for were not
received at the time of purchase or delivery.
LTM flange type
The mechanical connections for a Series 1500 LTM NPS 3 through 24 are standard class
150, 300, 600 and 900 ANSI S.O. R.F. flanges, which are available in stainless steel and
carbon. For class ratings 1500 and 2500 Daniel offers weld neck RTJ Daniel type flanges as
standard. Other types of flange connections are available per customer request. For other
ANSI ratings or flanges consult the factory engineers. For maximum working pressures at
intermediate temperatures refer to ANSI B16.5.
WARNING!
HIGH PRESSURE HAZARD
Choose the appropriate size and material of the flange for their piping requirements.
Choosing an incorrect flange may cause a pressure leak, resulting in death or serious injury.
2.2.2
Requirements and limitations for installation
Typical installation for a Series 1500 LTM
Figure 2-2:
•
Note the direction of flow indicated on the plate near the inlet flange and install accordingly.
•
New installations: Flush lines thoroughly to rid piping of potentially damaging foreign material
such as welding bead, pipe scale, etc. before the turbine meter is placed into service.
Operating conditions and specifications
36
Daniel Series 1500 Liquid Turbine Meter, NPS 3-24
Summary of Contents for daniel 1500 series
Page 8: ......
Page 12: ...Plan 2 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 64: ...Prepare the turbine meter for use 54 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 66: ...Install 56 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 72: ...Installation procedure 62 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 74: ...Testing 64 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 75: ...Part III Operate Operate User manual 65 ...
Page 76: ...Operate 66 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 80: ...Maintain 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 101: ...Decommission the turbine meter User manual 91 ...
Page 102: ...Decommission the turbine meter 92 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 103: ...Decommission the turbine meter User manual 93 ...