Configuration
[43]
8
Configuration
Topics covered in this chapter:
•
General configuration procedure
•
Start of an offline configuration
•
Start of an online configuration
•
Configuration of an already existing converter
•
Configuration editor and parameters
•
Send and Reload a configuration
•
•
Components database – add a new target material
8.1
General configuration procedure
The configuration can be performed offline without connection to the EZ 1000 converter
or online with a connection to the converter. In any case, the configuration must be loaded
to the converter to become active.
Prerequisites
•
USB cable with Type-A and micro-USB B plug
Note
The USB interface is designed for configuration, maintenance, and trouble-shooting
purposes. Do not leave the USB Interface permanently connected.
•
Latest version of Machine Studio (configuration software)
Note
For general description of the configuration software, see operating manual "Machine
Studio – General Functions" (MHM-97879).
•
PC or laptop with Microsoft Windows 7 or higher
For intrinsically safe operations, use a battery powered device with a battery voltage
of less than 30 V (see
8.1.1
Offline configuration overview
1.
Start Machine Studio.
2.
Enter configuration parameter according to the used eddy current sensor and the
measuring task (see
Summary of Contents for AMS EZ1000