INSTALLER/CONFIGURATION MENU

To enter the Configuration Menu, SYSTEM must be set to 

HEAT

COOL

 or 

EMER

. Press the Menu button for at least 5 

seconds. The display will show item #1 in the table below. Press Menu button to advance to the next menu item. Press 

 or 

 to change a menu item.

INSTALLER/CONFIGURATION MENU        

MENU

SCREEN 

NUMBER

HP

MS/

SS

PRESS

BUTTON

DISPLAYED

(FACTORY DEFAULT)

Press 

 or 

 

to select from listed 

options

COMMENTS

01

MENU

(Off) 

Lk

L

Total Keypad lockout

(Not available on earlier models)

02

MENU

(000) Lk

001 to 999

Selects Keypad lockout combination number

03

MENU

(MS 2)

HP 1, HP 2, SS 1

Selects Multi-Stage (MS 2 No Heat Pump),

Heat Pump 1 (HP 1, 1 compressor), or 

Single Stage (SS 1), Heat Pump 2 (HP 2, 

2 compressor or 2 speed compressor)

04

MENU (GAS) for SS or MS

(ELE) for HP

ELE or 

GAS

GAS setting: furnace controls the blower

ELE setting: thermostat controls the blower

05

MENU

(0) CS

1, 2, 3, 4, 5, 6

Selects Cool Savings

Value 1 (low) to 6 (high), 

Value 0 Disables Feature

06

MENU

(ME) 

CR Heat

SL, FA

Adjustable Anticipation:

Selects heating cycle rate for MS or SS

07

MENU

(ME) 

CR Cool

SL, FA

Adjustable Anticipation:

Selects cool cycle rate

08

MENU

(ME) 

CR Heat Pump

SL, FA

Adjustable Anticipation (Heat Pump) (only

when heat pump selected in #1)

09

MENU

(FA)

CR Emer

SL, FA

SL

Selects the cycle rate for Emergency 

mode and Auxiliary stage if Heat Pump 

is selected in item 1.

10

MENU

(OFF) CL

CL On

Compressor Lockout Time Delay

11

MENU

Heat Auto

Cool Off

Heat Cool Off,

Heat Off with Fan icon,

Heat Off without Fan icon, 

Cool Off, Auto Off

Select System Switch Configuration

with Automatic Changeover capability.

12

MENU

(On) dL

dL OFF

Selects Display Light On or OFF

13

MENU

0

(current temperature)

1 HI, 2 HI, 3 HI, 4 HI,

1 LO, 2 LO, 3 LO, 4 LO

Adjustable Ambient Temperature Display

14

MENU

°

F

°

C

Selects Fahrenheit/Celsius 

Temperature Display

15

MENU

(90) L Heat

L 62 to L 89

Selects Limited HEAT Range

16

MENU

(45) L Cool

L 46 to L 82

Selects Limited COOL Range

17

MS MENU

(On) Heat FA

OFF

Fast Heat option may be disabled by

selecting OFF. NA to SS config. 

NA to Cool only system.

18

HP2

MENU

(On) Cool FA

OFF

Fast Cool option may be disabled by

selecting OFF. NA to SS config. 

NA to Heat only system.

19

MENU

(OFF) CA

On

Selects active Comfort Alert On or OFF. 

Requires CA II Module. 

(Not available on earlier models)

20

MENU (OFF) Change Filter

On

Selects Filter Change-out Indicator On or OFF.

21

MENU (200 h) Change Filter

25-1975 h

Change Filter time in 25 hour increments. This

menu only appears if On is selected in above.

22

MENU

(o) Cool On

(b) Heat On

Selects operation of the reversing valve termi-

nal (O/B) output as an O or B terminal.

Summary of Contents for 1F83-0471

Page 1: ...uct that contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and place in a sealed container For proper disposal of a product containing mercury or a sealed container of spilled mercury place it in a suitable shipping container Refer to www white rodgers com for ...

Page 2: ...ion To replace the batteries set system to OFF Thermostat can be powered by system AC power or Battery If is displayed the thermostat is battery powered If is not displayed thermostat is system powered with optional battery back up When battery power remaining is approxi mately half the will be displayed When Change is displayed install fresh AA alkaline batteries immediately For best results repl...

Page 3: ...p with Single Transformer Common connection required for fault or malfunction indication Single Stage 1 SS1 Multi Stage 2 MS2 O Energized Constantly in Cool Mode B Energized Constantly in Heat Off Emergency Mode No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower Circulator Fan Energized on Call for Cool and Heat if configured for Electric Heat No Output Heat Mode 2nd Stage Heat Mode 1st Stag...

Page 4: ...heating or cooling stage is energized 2 flashing indicates when a second stage is energized 2 not flashing when Aux is energized 2 The word Set indicates the setpoint temperature 3 Displays Change Filter when the system has run for the programmed filter time period as a reminder to change or clean your filter 4 Displays System Mode Heat Emer Auto Cool Off in Menu Mode 5 Displays Fan Mode On Auto o...

Page 5: ...ly when heat pump selected in 1 09 MENU FA CR Emer SL FA SL Selects the cycle rate for Emergency mode and Auxiliary stage if Heat Pump is selected in item 1 10 MENU OFF CL CL On Compressor Lockout Time Delay 11 MENU Heat Auto Cool Off Heat Cool Off Heat Off with Fan icon Heat Off without Fan icon Cool Off Auto Off Select System Switch Configuration with Automatic Changeover capability 12 MENU On d...

Page 6: ...play will show Save next to the setpoint temperature When Cool Savings is making ad justments to the room temperature display Save will be flashing and the displayed room temperature may vary within the adjustment range you selected If Save is not displayed and this feature is OFF no change will occur when the cooling system is continu ously running during periods of high demand 6 7 8 9 Cycle Rate...

Page 7: ...stat will display Change Filter as a reminder to change or clean your air filter When Change Filter is displayed press MENU or RUN SCHED button to clear the display and restart the time to the next filter change 22 Select Reversing Valve Output The O B option is factory set at O position This will accommodate the majority of heat pump applications which require the changeover relay to be energized...

Page 8: ...hase for a replacement If the thermostat clicks contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly No Cool 1 Cooling system requires service or thermostat requires replacement Same as diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature There may be up to a five minute delay before t...

Page 9: ...o con el lugar de compra para obtener un reemplazo Si el termostato hace un chasquido póngase en contacto con el fabricante del calefactor o con el personal técnico para verificar que la calefacción esté funcionando correctamente El sistema no enfría 1 E l sistema de enfriamiento requiere servicio técnico o debe cambiarse el termostato Siga el mismo procedimiento de diagnóstico que Cuando el siste...

Page 10: ...nversora La opción O B viene ajustada de fábrica en la posición O Esta opción admite la mayoría de las aplicaciones de bomba de calor que requieren que el relé de conmutación esté energizado en COOL Si el termostato que está cambiando o la bomba de calor que está instalando con este termostato requiere una terminal B para energizar el relé de conmutación en HEAT el interruptor O B debe colocarse e...

Page 11: ...orma intermitente y la temperatura ambiente visualizada podrá variar dentro del rango de ajuste seleccionado Si no aparece la palabra Save y esta función está en OFF no se realizarán cambios cuando el sistema de enfriamiento esté funcionando de forma continua durante períodos de alta demanda 6 7 8 y 9 Selección de la velocidad del ciclo El ajuste predeterminado de fábrica para los modos Heat y Coo...

Page 12: ...r SL FA SL Selecciona la velocidad del ciclo para el modo Emergency y etapa auxiliar si se ha seleccionado bomba de calor en la opción 1 10 MENÚ OFF CL CL On Tiempo del bloqueo del compresor 11 MENÚ Heat Auto Cool Off Heat Cool Off Heat Off con icono de ventilador Heat Off sin icono de ventilador Cool Off Auto Off Selecciona Configuración de interruptor del sistema con capacidad de conmutación aut...

Page 13: ...izada 2 intermitente indica que está energizada una segunda etapa 2 sin parpadear cuando Aux está energizado 2 Muestra Set para ajustar la temperatura de referencia 3 Muestra Change Filter cuando el sistema se ha utilizado por la cantidad de tiempo selecionada en el filtro para recordarle que debe cambiar o limpiar el filtro de aire 4 Muestra el modo del sistema Heat Emer Auto Cool Off en el modo ...

Page 14: ...de una sola etapa o multietapa sin bomba de calor con un solo transformador Se requiere una conexión neutra para indicación de falla o desperfecto Una sola etapa 1 SS1 Multietapa 2 MS2 O Energizado de forma constante en modo Cool B Energizado de forma constante en modo Heat Off Emergency No salida Modo Cool 2º etapa Modo Cool 1º etapa No salida Modo Heat 2º etapa Modo Heat 1º etapa Opcional 24 vol...

Page 15: ...o está funcionando con pilas Si el símbolo no aparece significa que el termostato está funcionando con la alimentación del sistema y además cuenta con alimentación auxiliar opcional con pilas Cuando la carga de las pilas se encuentra aproximadamente en la mitad aparecerá el símbolo Cuando aparezca el mensaje Change Cambiar instale dos pilas alcalinas AA nuevas inmediatamente Para obtener resultado...

Page 16: ...tienen mercurio no deben desecharse con los residuos domésticos No toque el mercurio derramado Usando un par de guantes no absorbentes recoja el mercurio derramado y viértalo en un recipiente sellado Para desechar de forma adecuada un producto que contiene mercurio o un recipiente sellado con mercurio derramado colóquelo en un contenedor de transporte adecuado En www white rodgers com se indican l...

Reviews: