background image

1

Ter

mostato univ

ersal Blue 4 pulg. con 

opción de conmutación automática calor/frío

Una sola etapa, m

ultietapa o bomba de calor

Instrucciones de instalación y operación para el modelo:

EL NO LEER  Y SEGUIR CON CUID

ADO TOD

AS LAS 

INSTRUCCIONES ANTES DE INST

ALAR O UTILIZAR ESTE 

CONTROL PODRÍA CA

USAR LESIONES PERSONALES  Y/O 

DAÑOS MA

TERIALES.

¡Conserve estas instrucciones para 

consultarlas en cualquier momento!

APLICACIONES 

ESPECIFICACIONES 

Características eléctr

icas:

 

Alimentación con pilas.................................................

 mV a 30 

VCA, NEC Clase II, 50/60 Hz o CC

 

Entrada-Cab

leado interno

 ...........................................

 20 a 30 

VCA

Carga en terminales

 ............................................................

 1.5 A por ter

minal, 2.5 A máx. en todas las ter

minales combinadas

Rango de temperatur

a de referencia

 ...................................

 45° a 90°F (7° a 32°C)

Diferencial 

Valor

ado:                                                              Rápido

 

Medio 

Lento

 

Calor (Una sola etapa/Multietapa)...............................

 0.4 °F

 

0.6 °F 

1.7 °F

 

Frío (Una sola etapa/Multietapa)

 .................................

 0.9 °F

 

1.2 °F 

1.7 °F

 

Bomba de Calor ..........................................................

 0.9 °F

 

1.2 °F 

1.7 °F

 

Calefacción A

uxiliar .....................................................

 0.6 °F

 

    – 

1.7 °F

T emper

atura ambiente oper

ativa 

......................................... 

32° a +105°F (0° a +41°C)

Humedad operativ

a .............................................................

 90% sin condensación máx.

Rango de temperatur

a de transpor

te ..................................

 -40° a +150°F (-40° a +65°C)

Dimensiones del termostato

 ................................................

 3-7/8 pulg.

 Al x 5-1/8 pulg. An x 1-1/4 pulg.

 P

Termostato 1F83-0471 

Modelo

Opciones de programación

1F83-0471

No programab

le

ATENCIÓN:

 NOTA SOBRE EL MERCURIO 

Este producto no contiene mercurio

. No obstante

,  puede reemplazar 

un producto que sí contiene mercurio

.   

El mercurio y los productos que contienen mercur

io no deben 

desecharse con los residuos domésticos. No toque el mercur

io 

derramado

. Usando un par de guantes no absorbentes

, recoja 

el mercurio derr

amado y viértalo en un recipiente sellado

. P

ara 

desechar de for

ma adecuada un producto que contiene mercurio 

o un recipiente sellado con mercurio derr

amado, colóquelo en un 

contenedor de 

transpor

te adecuado

. En 

www.white-r

odger

s.com 

se indican los lugares a los que se pueden enviar los productos que 

contienen mercurio

.

Para e

vitar descargas eléctricas y/o daños al equipo,

 

desconecte la alimentación eléctrica al sistema en la caja de 

fusibles o disyuntores principal hasta que ha

ya finalizado 

la instalación.

¡PRECAUCIÓN!

!

GUÍA DE APLICACIONES DEL 

TERMOSTAT

O

Descripción 

Bomba de calor (sin calor auxiliar o de emergencia)

Bomba de calor (con calor auxiliar o de emergencia)

Sistema con hasta 2 etapas de calor, 2 etapas de frío

Sistemas de sólo calor (con interruptor de v

entilador opcional)

Sistemas de sólo calor milivoltios –

 Calefactores de piso o pared

Sistemas de sólo enfriamiento

Sistemas de calefacción de gas o aceite

Calefactor eléctr

ico

Calefacción z

onificada hidrónica (agua caliente) – 2 cables

Calefacción z

onificada hidrónica (agua caliente) – 3 cables

Compresor con modulo de  Alerta de comodidad II (sólo 1F85CA)

Índice

Página

Instalación 

2

Conexiones eléctr

icas

2

Diagrama de cone

xiones

3

Guía de referencia rápida del ter

mostato

4

Menú instalador/de configuración

5

Cómo usar su termostato

7

Solución de problemas

7

N° DE PIEZA 37-7237A

1117

www.white-rodgers

.com

www.emersonclimate

.com

Summary of Contents for 1F83-0471

Page 1: ...uct that contains mercury Mercury and products containing mercury must not be discarded in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and place in a sealed container For proper disposal of a product containing mercury or a sealed container of spilled mercury place it in a suitable shipping container Refer to www white rodgers com for ...

Page 2: ...ion To replace the batteries set system to OFF Thermostat can be powered by system AC power or Battery If is displayed the thermostat is battery powered If is not displayed thermostat is system powered with optional battery back up When battery power remaining is approxi mately half the will be displayed When Change is displayed install fresh AA alkaline batteries immediately For best results repl...

Page 3: ...p with Single Transformer Common connection required for fault or malfunction indication Single Stage 1 SS1 Multi Stage 2 MS2 O Energized Constantly in Cool Mode B Energized Constantly in Heat Off Emergency Mode No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower Circulator Fan Energized on Call for Cool and Heat if configured for Electric Heat No Output Heat Mode 2nd Stage Heat Mode 1st Stag...

Page 4: ...heating or cooling stage is energized 2 flashing indicates when a second stage is energized 2 not flashing when Aux is energized 2 The word Set indicates the setpoint temperature 3 Displays Change Filter when the system has run for the programmed filter time period as a reminder to change or clean your filter 4 Displays System Mode Heat Emer Auto Cool Off in Menu Mode 5 Displays Fan Mode On Auto o...

Page 5: ...ly when heat pump selected in 1 09 MENU FA CR Emer SL FA SL Selects the cycle rate for Emergency mode and Auxiliary stage if Heat Pump is selected in item 1 10 MENU OFF CL CL On Compressor Lockout Time Delay 11 MENU Heat Auto Cool Off Heat Cool Off Heat Off with Fan icon Heat Off without Fan icon Cool Off Auto Off Select System Switch Configuration with Automatic Changeover capability 12 MENU On d...

Page 6: ...play will show Save next to the setpoint temperature When Cool Savings is making ad justments to the room temperature display Save will be flashing and the displayed room temperature may vary within the adjustment range you selected If Save is not displayed and this feature is OFF no change will occur when the cooling system is continu ously running during periods of high demand 6 7 8 9 Cycle Rate...

Page 7: ...stat will display Change Filter as a reminder to change or clean your air filter When Change Filter is displayed press MENU or RUN SCHED button to clear the display and restart the time to the next filter change 22 Select Reversing Valve Output The O B option is factory set at O position This will accommodate the majority of heat pump applications which require the changeover relay to be energized...

Page 8: ...hase for a replacement If the thermostat clicks contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly No Cool 1 Cooling system requires service or thermostat requires replacement Same as diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature There may be up to a five minute delay before t...

Page 9: ...o con el lugar de compra para obtener un reemplazo Si el termostato hace un chasquido póngase en contacto con el fabricante del calefactor o con el personal técnico para verificar que la calefacción esté funcionando correctamente El sistema no enfría 1 E l sistema de enfriamiento requiere servicio técnico o debe cambiarse el termostato Siga el mismo procedimiento de diagnóstico que Cuando el siste...

Page 10: ...nversora La opción O B viene ajustada de fábrica en la posición O Esta opción admite la mayoría de las aplicaciones de bomba de calor que requieren que el relé de conmutación esté energizado en COOL Si el termostato que está cambiando o la bomba de calor que está instalando con este termostato requiere una terminal B para energizar el relé de conmutación en HEAT el interruptor O B debe colocarse e...

Page 11: ...orma intermitente y la temperatura ambiente visualizada podrá variar dentro del rango de ajuste seleccionado Si no aparece la palabra Save y esta función está en OFF no se realizarán cambios cuando el sistema de enfriamiento esté funcionando de forma continua durante períodos de alta demanda 6 7 8 y 9 Selección de la velocidad del ciclo El ajuste predeterminado de fábrica para los modos Heat y Coo...

Page 12: ...r SL FA SL Selecciona la velocidad del ciclo para el modo Emergency y etapa auxiliar si se ha seleccionado bomba de calor en la opción 1 10 MENÚ OFF CL CL On Tiempo del bloqueo del compresor 11 MENÚ Heat Auto Cool Off Heat Cool Off Heat Off con icono de ventilador Heat Off sin icono de ventilador Cool Off Auto Off Selecciona Configuración de interruptor del sistema con capacidad de conmutación aut...

Page 13: ...izada 2 intermitente indica que está energizada una segunda etapa 2 sin parpadear cuando Aux está energizado 2 Muestra Set para ajustar la temperatura de referencia 3 Muestra Change Filter cuando el sistema se ha utilizado por la cantidad de tiempo selecionada en el filtro para recordarle que debe cambiar o limpiar el filtro de aire 4 Muestra el modo del sistema Heat Emer Auto Cool Off en el modo ...

Page 14: ...de una sola etapa o multietapa sin bomba de calor con un solo transformador Se requiere una conexión neutra para indicación de falla o desperfecto Una sola etapa 1 SS1 Multietapa 2 MS2 O Energizado de forma constante en modo Cool B Energizado de forma constante en modo Heat Off Emergency No salida Modo Cool 2º etapa Modo Cool 1º etapa No salida Modo Heat 2º etapa Modo Heat 1º etapa Opcional 24 vol...

Page 15: ...o está funcionando con pilas Si el símbolo no aparece significa que el termostato está funcionando con la alimentación del sistema y además cuenta con alimentación auxiliar opcional con pilas Cuando la carga de las pilas se encuentra aproximadamente en la mitad aparecerá el símbolo Cuando aparezca el mensaje Change Cambiar instale dos pilas alcalinas AA nuevas inmediatamente Para obtener resultado...

Page 16: ...tienen mercurio no deben desecharse con los residuos domésticos No toque el mercurio derramado Usando un par de guantes no absorbentes recoja el mercurio derramado y viértalo en un recipiente sellado Para desechar de forma adecuada un producto que contiene mercurio o un recipiente sellado con mercurio derramado colóquelo en un contenedor de transporte adecuado En www white rodgers com se indican l...