Towerstat RF/BM 

 

The Towerstat RF/BM consists of a free-standing battery-powered (2 x AA alkaline) 
radio-frequency transmitter (TX), and a ‘boiler module’, which is a boiler-mounted 
modular receiver (RX).  The boiler module RX is mains powered by connecting to 
existing wiring within the boiler, and controls a volt-free changeover switch according 
to signals from the TX.  The TX and RX must be linked by the RF setup process (see 
below).  The transmitter can then be positioned freely around the property, and will 
control the boiler to bring the heating on and off according to automatic or manual 
settings on the transmitter. 
 
The transmitter can be programmed with two temperature levels: daytime (comfort) 
and night set-back (economy).  The transmitter can also hold a time programme to 
provide automatic control of those daytime comfort and night-set back economy 
temperatures.  This will allow you to pre-set a programme as illustrated below.  The 
transmitter programme positions P1 – P6 are factory pre-set sequences which 
cannot be altered.  P7, P8 & P9 are user-adjustable programmes so that you can 
enter a time programme of your choosing, with settings at one-hour intervals. 
 
 
 
 
 
 

Pre-set programme – example 

 
The boiler module RX must be installed by a qualified person.  We recommend 
that you obtain the services of a CORGI registered heating installer for any 
work within your boiler.   
You can find registered installers in your area by calling 0870 401 2200   
Or visit http://www.trustcorgi.com/consumers.htmx 

 

Boiler module RX installation 

 
N.B. some boiler control panels have a hinged steel cover.  These are likely to 
be unsuitable for the boiler-mounted modular receiver, as the steel cover will 
effectively block the radio frequency transmissions between the transmitter 
and receiver.  In general you should avoid positioning metallic objects – 
including mirrors - in the line-of-sight between transmitter and receiver. 
 

Switch off the mains power to the boiler, and obtain access to the boiler control panel 
following the manufacturer’s instructions.  Boilers which are suitable for the 
Towerstat RF/BM boiler module RX will already have a mechanical or digital timer 
fitted, or may have a blanking-plate to cover the aperture where the timer can be 
fitted.  The boiler module RX can be fixed in place as a direct replacement for the 
timer, and should be connected in the same way as the original timing device.  
Boilers should have four electrical connections only, to the terminals marked 1 to 4.  
In these cases the boiler module RX can be connected in the same way.   
 
 

Time:  00:00 

06:00

12:00

18:00 

Comfort 

Economy 

Summary of Contents for RF

Page 1: ... boiler module RX must be installed by a qualified person We recommend that you obtain the services of a CORGI registered heating installer for any work within your boiler You can find registered installers in your area by calling 0870 401 2200 Or visit http www trustcorgi com consumers htmx Boiler module RX installation N B some boiler control panels have a hinged steel cover These are likely to ...

Page 2: ...X are now linked 5 If the TX ID code has been left at the default value of 100 there is no need to re apply the RF linking procedure following replacement of TX batteries 6 If the TX batteries are removed or go flat and the TX is without battery power for more than 1 minute you should ensure to go through operations 1 to 3 of this sequence again to re establish the RF link which would otherwise be...

Page 3: ...e button The pre set programme is now set for the day or day group chosen at step 2 above Set your own time programme 1 Follow steps 1 to 4 above At step 4 scroll with the up arrow button to P7 P8 or P9 These are three programme entries which are user adjustable You can apply one or all user adjustable programmes to any day or day group of your choice 2 Press the set programme button Above the P n...

Page 4: ...tional buttons A backlight button press this once and a blue backlight will illuminate the display for 15 seconds or as long as buttons continue to be pressed and will then extinguish after a further 15 seconds Note that repeated use of the backlight facility will reduce battery life A reset button accessible only with e g a pencil or biro in the lower left corner of the keypad array Operation of ...

Page 5: ...ter receiver detail Transmitter TX operating supply 2 x AA alkaline Battery life approx 1 year Control range 7 0 C to 30 0 C Measurement range 0 0 C to 40 0 C in 0 5 0 C increments Temperature accuracy 1 0 0 C 20 0 C Programme graphic Demand indicator rotating Weekday indicator Time display Mode indicator low battery warning Override indicator Programme number Ambient temperature Set temperature b...

Page 6: ...ed button for ID learning Connections 1 Neutral input 2 Live input 3 Common input 4 Normally open output Applicable regulatory compliance CE directive Electromagnetic compatibility Low Voltage R TTE directive Radio and Telecommunications Terminal Equipment Battery insertion To separate the two halves of the outer housing follow the diagram below Insert the batteries into the battery compartment En...