background image

www.white-rodgers.com

3

 REMOVING OLD THERMOSTAT 

         CONTINUED FROM FIRST PAGE

ATTENTION! This product does not contain mercury. However, this 
product may replace a unit which contains mercury.
Do  not  open  mercury  cells.  If  a  cell  becomes  damaged,  do  not 
touch any spilled mercury. Wearing non-absorbent gloves, take up 
the spilled mercury and place into a container which can be sealed. 
If a cell becomes damaged, the unit should be discarded.
Mercury must not be discarded in household trash. When the unit 
this product is replacing is to be discarded, place in a suitable con-
tainer. Refer to www.white-rodgers.com for locations to send prod-
uct containing mercury.

4

 MOUNTING AND WIRING

Do not use on circuits exceeding specified voltage. Higher 
voltage will damage control and could cause shock or fire 
hazard.
Do not short out terminals on gas valve or primary control 
to test. Short or incorrect wiring will damage thermostat 
and could cause personal injury and/or property damage. 
Thermostat installation and all components of the system 
shall conform to Class II circuits per the NEC code.

Electric Heat or Single-Stage 

Heat Pump Systems

This thermostat is configured from the factory to operate a heat/
cool,  fossil  fuel  (gas,  oil,  etc.),  forced  air  system.  It  is  configured 
correctly  for  any  system  that  DOES  NOT  require  the  thermostat 
to energize the fan on a call for heat. If your system is an electric 
or  heat-pump  system  that  REQUIRES  the  thermostat  to  turn  on 
the fan on a call for heat, locate the 

GAS/ELECTRIC switch (see 

fig. 1) and switch it to the 

ELECTRIC position. This will allow the 

thermostat to energize the fan immediately on a call for heat. If you 
are  unsure  if  the  heating/cooling  system  requires  the  thermostat 
to control the fan, contact a qualified heating and air conditioning 
service person.

Hydronic (Hot Water or Steam)  

Heating Systems

This thermostat is set to operate properly with a forced-air heating 
system. If you have a hydronic heating system (a system that heats 
with hot water or steam), you must set the thermostat to operate 
properly with your system.
The factory default setting is forced air heat. Clipping jumper W905 
on  the  circuit  board  will  produce  a  longer  heating  cycle  which  is 
normally for hot water or steam (hydronic) systems. Both settings 
produce a very accurate temperature control and can be set to your 
personal preference. As received, the thermostat cycles the system 
just under 1°F. With W905 clipped, the system cycles at approxi-
mately 1.5°F.

Take care when securing and routing wires so they do not 
short to adjacent terminals or rear of thermostat. Personal 
injury and/or property damage may occur.

CAUTION

!

TERMINAL CROSS REFERENCE CHART

New Thermostat

Terminal Designation

Other Manufacturers’

Terminal Designation

RH
RC

G

W

Y

4

R
G

W

Y

RH

R
G

W

Y

M

V
F
H
C

R5

-

G

4

Y6

R

-

G

W

Y

*

*

*  These are four-wire, single-transformer systems.

    Factory installed jumper wire between the 

RH

    and 

RC terminals must remain in place.

Energy Management Recovery (EMR)

This  thermostat    is  set  to  operate  with  EMR.  This  causes  the 
thermostat  to  start  the  heating  or  cooling  system  early  to  have  
the  room  temperature  reach  the  program  setpoint  at  the  time  
the period is to start.
To disable EMR, clip jumper W903 (see Fig. 1).

Attach Thermostat Base to Wall

1.  Remove the packing material from the thermostat. Gently pull 

the  cover  straight  off  the  base.  Forcing  or  prying  on  the  ther-
mostat  will cause  damage  to  the  unit.  If  necessary,  move  the 
electric heat switch (see 

ELECTRIC HEAT SYSTEMS, above).

2.  Connect wires beneath terminal screws on base using appro-

priate wiring schematic (see figs. 2 through 7).

3.  Place base over hole in wall and mark mounting hole locations 

on wall using base as a template.

4.  Move base out of the way. Drill mounting holes.
5.  Fasten base loosely to wall, as shown in fig. 1, using two mount-

ing screws. Adjust until level, and then tighten screws. (Leveling 
is for appearance only and will not affect thermostat operation.) 
If you are using existing mounting holes, or if holes drilled are 
too large and do not allow you to tighten base snugly, use plas-
tic screw anchors to secure subbase.

6.  Push  excess  wire  into  wall  and  plug  hole  with  a  fire-resistant 

material  (such  as  fiberglass  insulation)  to  prevent  drafts  from 
affecting thermostat operation.

Battery Location

This  thermostat  requires  2 “AAA”  alkaline  batteries  to  operate.

  If 

 is displayed, the batteries are low and should be re-

placed. For best results, replace batteries once a year with new pre-
mium brand alkaline batteries such as Duracell

® 

or Energizer

®

. To 

replace the batteries, install the batteries along the top of the base 
(see  fig.  1).  The  batteries  must  be  installed  with  the  positive (+) 
ends to the right.

WARNING

!

Summary of Contents for 1F78

Page 1: ...mostat With wires still attached remove wall plate from the wall If the old thermostat has a wall mounting plate remove the thermostat and the wall mounting plate as an assembly 4 Identify each wire attached to the old thermostat 5 Disconnect the wires from the old thermostat one at a time DO NOT LET WIRES FALL BACK INTO THE WALL 6 Install new thermostat using the following procedures PART NO 37 6...

Page 2: ...onic systems Both settings produce a very accurate temperature control and can be set to your personal preference As received the thermostat cycles the system just under 1 F With W905 clipped the system cycles at approxi mately 1 5 F Take care when securing and routing wires so they do not short to adjacent terminals or rear of thermostat Personal injury and or property damage may occur CAUTION TE...

Page 3: ...ER WIRE Reversing valve is energized when the system switch is in the HEAT position Fan Relay 5 CHECK THERMOSTAT OPERATION NOTE To prevent static discharge problems touch side of thermo stat to release static build up before touching any keys If at any time during testing your system does not operate properly contact a qualified service person Fan Operation If your system does not have a G termina...

Page 4: ...the next program period be gins Then the thermostat will automatically revert to the pro gram HOLD TEMPERATURE The thermostat can hold any tem perature within its range for an indefinite period without re verting to the programmed temperature Press HOLD button HOLD will be displayed Then choose the desired temper ature by pressing or The thermostat will hold the room temperature at the selected se...

Page 5: ...es you want during each period You may also want to look at the sample program table to get an idea of how the thermostat can be programmed 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH SAMPLE Heating Cooling Schedule Plan Factory Program 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 70 F 62 F 70 F 62 F 78 F 85 F 78 F 82 F 70 ...

Page 6: ... TO AUTOMATICALLY PROVIDE MAXIMUM COMFORT AND EFFICIENCY 7 SPECIFICATIONS ELECTRICAL DATA Electrical Rating MV to 30 VAC 50 60 Hz or D C 0 05 to 1 0 Amps Load per terminal 1 5 Amps Maximum Total Load All terminals combined THERMAL DATA Setpoint Temperature Range 45 F to 90 F 7 C to 32 C Operating Ambient Temperature Range 32 F to 105 F 0 C to 41 C Operating Humidity Range 0 to 90 RH non condensing...

Page 7: ...to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Furnace Cycles Too Fast or Too Slow narrow or wide temperature swing The location of the thermostat and or 1 the size of the Heating System may be influencing the cycle rate Digital thermostats normally provide precise temperature control and may cycle faster than some older mechanical models...

Page 8: ...White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 www white rodgers com www emersonclimate com ...

Page 9: ... com www emersonclimate com LÍNEA DE AYUDA PARA EL USUARIO 1 800 284 2925 White Rodgers es una división de Emerson Electric Co El logotipo de Emerson es una marca comercial y una marca de servicio de Emerson Electric Co ...

Page 10: ...ncionando correctamente Si el sistema funciona correctamente cambie el termostato Los ciclos de la caldera son 1 La ubicación del termostato y o el tamaño del Normalmente los termostatos digitales proporcionan un demasiado cortos o demasiado sistema de calefacción pueden influir en la control preciso de la temperatura y pueden apagarse y largos oscilación reducida o duración de los ciclos encender...

Page 11: ... AUTOMÁTICA EL MÁXIMO CONFORT Y EFICIENCIA 7 ESPECIFICACIONES DATOS ELÉCTRICOS Características eléctricas MV a 30 VCA 50 60 Hz o CC 05 a 1 0 amps carga por terminal Carga total máxima 1 5 amps todas las terminales combinadas DATOS TÉRMICOS Rango de temperaturas de referencia 45 F a 90 F 7 C a 32 C Temperatura ambiente operativa 32 F a 105 F 0ºC a 41ºC Humedad operativa 0 a 90 HR sin condensación T...

Page 12: ...igeración para el programa semanal Utilice la tabla que se encuentra al pie de la página para planificar las horas y temperaturas de programación que desea durante cada período También puede consultar la tabla de ejemplos de programas para tener una idea de cómo programar el termostato 1 2 3 4 1 2 3 4 EJEMPLO Plan de programación de calefacción refrigeración programa de fábrica 6 00 AM 8 00 AM 5 0...

Page 13: ...a MANTENER TEMPERATURA El termostato puede mantener cual quier temperatura dentro de su rango por un tiempo indefinido sin volver a la temperatura programada Presione el botón HOLD Apare cerá HOLD en la pantalla Luego elija la temperatura deseada pre sionando o El termostato mantendrá la temperatura am biente al valor seleccionado hasta que presione el botón RUN para volver a iniciar la ejecución ...

Page 14: ...ERIFIQUE EL FUNCIONAMIENTO DEL TERMOSTATO NOTA Para evitar problemas de descarga estática toque la parte lateral del termostato para liberar la estática acumulada antes de pulsar cualquier tecla Si en algún momento durante la prueba su sistema no funciona correcta mente póngase en contacto con un servicio técnico calificado Funcionamiento del ventilador Si su sistema no tiene una conexión terminal...

Page 15: ...exacto y pueden ajustarse según su preferencia personal Tal como se envía de fábrica el termostato apaga y enciende el sistema debajo de 1 F Con el cable de puente W905 cortado el sistema se apagará y encenderá a aproximadamente 1 5 F Al fijar y pasar los cables tenga cuidado de que no hagan cortocircuito con las terminales adyacentes o en la parte trasera del termostato Podrían producirse lesione...

Page 16: ...esión o articulada b La base que se quita aflojando todos los tornillos imperdibles c La subbase de conmutación que se quita desenroscando los tornillos de montaje que la sostienen sobre la pared o la placa adaptadora 2 Apague la electricidad en la caja de fusibles principal hasta que haya finalizado la instalación Asegúrese de que la alimentación eléctrica esté desconectada 3 Retire la cubierta d...

Reviews: