background image

www.white-rodgers.com

6

 PROGRAMMING YOUR THERMOSTAT

play to match your old thermostat. This can be accomplished 
(within a ±3° range) as follows:
1.  Press PRGM and RUN buttons at the same time.
2.  Press 

 or 

 to adjust the displayed temperature to 

your desired setting.

3.  Press RUN to resume normal program operation.

• 

Display Backlight — (Not available on earlier models.) The 
display  backlight  improves  display  contrast  in  low  lighting 
conditions. Selecting backlight ON will turn the light on for 
a short period of time after any button is pressed. Selecting 
backlight OFF (default) will keep the light off. Turn the dis-
play backlight feature ON as follows:

1.  Press TIME and RUN buttons at the same time. The display 

will show 

“d-L” and “OFF” alternately.

2.  Press 

 or 

 to change 

“OFF” to “ON” 

This section will help you plan your thermostat’s program to meet 
your needs. For maximum comfort and efficiency, keep the follow-
ing guidelines in mind when planning your program.

•  When  heating  (cooling)  your  building,  program  the  tempera

-

tures to be cooler (warmer) when the building is vacant or dur-
ing periods of low activity.

•  During  early  morning  hours,  the  need  for  cooling  is  usually 

minimal.

Look at the factory preprogrammed times and temperatures shown 
below. If this program will suit your needs, simply press the RUN 
button to begin running the factory preset program.
If you want to change the preprogrammed times and temperatures, 
follow these steps.
Determine  the  time  periods  and  temperatures  for  your  weekday 
and weekend programs. You must program four periods for both the 
weekday and weekend program. However, you may use the same 
heating and cooling temperatures for consecutive time periods. You 
can  choose  start  times,  heating  temperatures,  and  cooling  tem-
peratures independently for both weekday and weekend programs 
(for example, you may select 5:00 AM and 70° as the weekday 

1st 

period heating start time and temperature, and also choose 7:00 
AM  and  76°  as  the  weekday 

1st  period  cooling  start  time  and 

temperature). Use the table at the bottom of the page to plan your 
program time periods and the temperatures you want during each 
period. You may also want to look at the sample program table to 
get an idea of how the thermostat can be programmed.

1ST

2ND

3RD

4TH

1ST

2ND

3RD

4TH

SAMPLE

Heating/Cooling Schedule Plan (Factory Program)

6:00 AM

8:00 AM

5:00 PM

10:00 PM

6:00 AM

8:00 AM

5:00 PM

10:00 PM

6:00 AM

8:00 AM

5:00 PM

10:00 PM

6:00 AM

8:00 AM

5:00 PM

10:00 PM

70 F

62 F

70 F

62 F

78 F

85 F

78 F

82 F

70 F

62 F

70 F

62 F

78 F

85 F

78 F

82 F

WEEKDAY (5 DAY)

WEEKEND (2 DAY)

Start

Time

Temperature

Start

Time

Temperature

Period

COOL

HEA

T

Entering Your Program

Follow these steps to enter the heating and cooling programs you 
have selected.

Set Current Time and Day

1.  Press TIME button once. The display will show the hour only.

 

EXAMPLE: 

PM

 

2.  Press and hold either 

 or 

 until you reach the correct 

hour and AM/PM designation (

AM begins at midnight; PM be-

gins at noon).

3.  Press TIME  once. The  display  window  will  show  the  minutes 

only.

   

  EXAMPLE: 

4.  Press and hold either 

 or 

 until you reach the correct 

minutes.

5.  Press TIME once. The display will show the day of the week.
6.  Press 

 or 

 until you reach the current day of the week.

7.  Press  RUN once. The display will show the correct time and 

room temperature alternately.

Enter Heating Program

1.  Move the SYSTEM switch to 

HEAT.

2.  Press PRGM once. “A” (indicating weekday program) will appear 

in the display. Also displayed are the currently programmed start 
time for the 

1st heating period and the currently programmed 

temperature (flashing).

   

  EXAMPLE: 

AM

MO TU WE TH FR

This display window shows that for the 1st weekday period, the 
start time is 6:00 AM, and 70° is the programmed temperature 
(this example reflects factory preprogramming).

3.  Press 

 or 

 to change the displayed temperature to your 

selected temperature for the 1st heating program period. 

4.  Press TIME once (the programmed time will flash). Press 

 

or 

 until your selected time appears. The time will change 

in 15 minute increments. When your selected time is displayed, 
press TIME again to return to the change temperature mode.

5.  Press  PRGM  once. The  currently  programmed  start  time  and 

setpoint temperature for the 

2nd heating program period will 

appear.

WEEKDAY (5 DAY)

WEEKEND (2 DAY)

Start

Time

Temperature

Start

Time

Temperature

Heating/Cooling Schedule Plan

Period

COOL

1ST

2ND

3RD

4TH

1ST

2ND

3RD

4TH

COOL

HEA

T

Summary of Contents for 1F78

Page 1: ...mostat With wires still attached remove wall plate from the wall If the old thermostat has a wall mounting plate remove the thermostat and the wall mounting plate as an assembly 4 Identify each wire attached to the old thermostat 5 Disconnect the wires from the old thermostat one at a time DO NOT LET WIRES FALL BACK INTO THE WALL 6 Install new thermostat using the following procedures PART NO 37 6...

Page 2: ...onic systems Both settings produce a very accurate temperature control and can be set to your personal preference As received the thermostat cycles the system just under 1 F With W905 clipped the system cycles at approxi mately 1 5 F Take care when securing and routing wires so they do not short to adjacent terminals or rear of thermostat Personal injury and or property damage may occur CAUTION TE...

Page 3: ...ER WIRE Reversing valve is energized when the system switch is in the HEAT position Fan Relay 5 CHECK THERMOSTAT OPERATION NOTE To prevent static discharge problems touch side of thermo stat to release static build up before touching any keys If at any time during testing your system does not operate properly contact a qualified service person Fan Operation If your system does not have a G termina...

Page 4: ...the next program period be gins Then the thermostat will automatically revert to the pro gram HOLD TEMPERATURE The thermostat can hold any tem perature within its range for an indefinite period without re verting to the programmed temperature Press HOLD button HOLD will be displayed Then choose the desired temper ature by pressing or The thermostat will hold the room temperature at the selected se...

Page 5: ...es you want during each period You may also want to look at the sample program table to get an idea of how the thermostat can be programmed 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH SAMPLE Heating Cooling Schedule Plan Factory Program 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 6 00 AM 8 00 AM 5 00 PM 10 00 PM 70 F 62 F 70 F 62 F 78 F 85 F 78 F 82 F 70 ...

Page 6: ... TO AUTOMATICALLY PROVIDE MAXIMUM COMFORT AND EFFICIENCY 7 SPECIFICATIONS ELECTRICAL DATA Electrical Rating MV to 30 VAC 50 60 Hz or D C 0 05 to 1 0 Amps Load per terminal 1 5 Amps Maximum Total Load All terminals combined THERMAL DATA Setpoint Temperature Range 45 F to 90 F 7 C to 32 C Operating Ambient Temperature Range 32 F to 105 F 0 C to 41 C Operating Humidity Range 0 to 90 RH non condensing...

Page 7: ...to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Furnace Cycles Too Fast or Too Slow narrow or wide temperature swing The location of the thermostat and or 1 the size of the Heating System may be influencing the cycle rate Digital thermostats normally provide precise temperature control and may cycle faster than some older mechanical models...

Page 8: ...White Rodgers is a division of Emerson Electric Co The Emerson logo is a trademark and service mark of Emerson Electric Co Homeowner Help Line 1 800 284 2925 www white rodgers com www emersonclimate com ...

Page 9: ... com www emersonclimate com LÍNEA DE AYUDA PARA EL USUARIO 1 800 284 2925 White Rodgers es una división de Emerson Electric Co El logotipo de Emerson es una marca comercial y una marca de servicio de Emerson Electric Co ...

Page 10: ...ncionando correctamente Si el sistema funciona correctamente cambie el termostato Los ciclos de la caldera son 1 La ubicación del termostato y o el tamaño del Normalmente los termostatos digitales proporcionan un demasiado cortos o demasiado sistema de calefacción pueden influir en la control preciso de la temperatura y pueden apagarse y largos oscilación reducida o duración de los ciclos encender...

Page 11: ... AUTOMÁTICA EL MÁXIMO CONFORT Y EFICIENCIA 7 ESPECIFICACIONES DATOS ELÉCTRICOS Características eléctricas MV a 30 VCA 50 60 Hz o CC 05 a 1 0 amps carga por terminal Carga total máxima 1 5 amps todas las terminales combinadas DATOS TÉRMICOS Rango de temperaturas de referencia 45 F a 90 F 7 C a 32 C Temperatura ambiente operativa 32 F a 105 F 0ºC a 41ºC Humedad operativa 0 a 90 HR sin condensación T...

Page 12: ...igeración para el programa semanal Utilice la tabla que se encuentra al pie de la página para planificar las horas y temperaturas de programación que desea durante cada período También puede consultar la tabla de ejemplos de programas para tener una idea de cómo programar el termostato 1 2 3 4 1 2 3 4 EJEMPLO Plan de programación de calefacción refrigeración programa de fábrica 6 00 AM 8 00 AM 5 0...

Page 13: ...a MANTENER TEMPERATURA El termostato puede mantener cual quier temperatura dentro de su rango por un tiempo indefinido sin volver a la temperatura programada Presione el botón HOLD Apare cerá HOLD en la pantalla Luego elija la temperatura deseada pre sionando o El termostato mantendrá la temperatura am biente al valor seleccionado hasta que presione el botón RUN para volver a iniciar la ejecución ...

Page 14: ...ERIFIQUE EL FUNCIONAMIENTO DEL TERMOSTATO NOTA Para evitar problemas de descarga estática toque la parte lateral del termostato para liberar la estática acumulada antes de pulsar cualquier tecla Si en algún momento durante la prueba su sistema no funciona correcta mente póngase en contacto con un servicio técnico calificado Funcionamiento del ventilador Si su sistema no tiene una conexión terminal...

Page 15: ...exacto y pueden ajustarse según su preferencia personal Tal como se envía de fábrica el termostato apaga y enciende el sistema debajo de 1 F Con el cable de puente W905 cortado el sistema se apagará y encenderá a aproximadamente 1 5 F Al fijar y pasar los cables tenga cuidado de que no hagan cortocircuito con las terminales adyacentes o en la parte trasera del termostato Podrían producirse lesione...

Page 16: ...esión o articulada b La base que se quita aflojando todos los tornillos imperdibles c La subbase de conmutación que se quita desenroscando los tornillos de montaje que la sostienen sobre la pared o la placa adaptadora 2 Apague la electricidad en la caja de fusibles principal hasta que haya finalizado la instalación Asegúrese de que la alimentación eléctrica esté desconectada 3 Retire la cubierta d...

Reviews: