Elsner Cala KNX AQS/TH Installation And Adjustment Download Page 55

53

Setting the parameters and functions for all 

Sensor with Cala KNX display

 • Version: 13.03.2017 • Technical changes and errors excepted.

Set the output send pattern.

Set the text to be displayed for conditions met / not met.

If applicable set the send delays.

Calculations and transformation

For calculations and transformations set the output values to the various conditions:

if the condition is met

0 [Input range depending on the type of 
output]

if the condition is not met

0 [Input range depending on the type of 
output]

if the monitoring time period 
is exceeded

0 [Input range depending on the type of 
output]

if blocked

0 [Input range depending on the type of 
output]

Output sends

• on change
• on change and after reset
• on change and periodically
• when receiving an input object
• when receiving an input object 
  and periodically

   Type of change

   (is only sent if "on change" is selected)

• on each change
• on change to condition met
• on change to condition not met

   Send cycle

   (if sent periodically)

5 s ... 2 h; 10 s

Text if the condition is met

[Free text max. 14 chars.]

Text if the condition is not met

[Free text max. 14 chars.]

Send delay in the event of change
to the condition is met

none • 1 s • ... • 2 h

Send delay in the event of change
to the condition is not met

none • 1 s • ... • 2 h

Output value (if applicable A1 / A2)

if the monitoring time period 
is exceeded

0 [Input range depending on the type of 
output]

if blocked

0 [Input range depending on the type of 
output]

Summary of Contents for Cala KNX AQS/TH

Page 1: ...603 black 70608 white Cala KNX TH 70602 black 70607 white Cala KNX T 70601 black 70606 white EN Cala KNX Indoor climate sensors with touch display Illustration with frame not included in the deliverab...

Page 2: ......

Page 3: ...1 Display settings 15 5 2 2 Button tone 19 5 2 3 Version 20 5 3 Sensor system measured value display 20 5 4 Temperature control 22 5 5 Light 23 5 6 Drive shading window 25 6 Transfer protocol 27 6 1 L...

Page 4: ...1 Threshold value 1 2 3 4 66 8 3 Temperature PI control 69 8 3 1 Heating control level 1 2 74 8 3 2 Cooling control level 1 2 76 8 4 Summer Compensation 78 9 Humidity parameter settings 80 9 1 Humidit...

Page 5: ...eshooting of the device must only be carried out by a competent electrician Safety advice Safety advice for working on electrical connections components etc DANGER indicates an immediately hazardous s...

Page 6: ...4 Clarification of signs...

Page 7: ...configuration There is one page available that shows the current measured values a menu area to adjust device settings and pages with touch control elements for internal temperature control for light...

Page 8: ...can be adjusted per parameter or via communication objects PI controller for heating one or two level and cooling one or two level according to temperature Regulation according to separate setpoints...

Page 9: ...D mm mounting depth approx 7 mm Total weight approx 90 gr incl supply line base plate Ambient temperature Operation 20 70 C storage 30 70 C Ambient humidity max 95 RH avoid condensation Operating vol...

Page 10: ...s the CO2 sensor performs a self calibration every two weeks in which the lowest CO2 value measured during this period without bus voltage interruption is tak en as a reference for fresh air In order...

Page 11: ...after conclusion of all installation and operational start up tasks and only in the surroundings designated for it Elsner Elektronik is not liable for any changes in norms and standards which may occ...

Page 12: ...es to the black red KNX plug and plug the KNX plug into the intended slot no 8 If required connect the analogue digital inputs via the breakout cable that is included in the delivery 3 5 7 8 6 1 Fig 1...

Page 13: ...ia the bus After the bus voltage has been applied the device will enter an initialisation phase lasting a few seconds During this phase no information can be received or sent via the bus 3 Addressing...

Page 14: ...12 Maintenance and care Sensor with Cala KNX display Version 13 03 2017 Technical changes and errors excepted...

Page 15: ...ettings Here you decide which menus are shown You call up the different menus on the display by swiping to the right or left You nav igate to sub menus via the touch keys and the navigation bar at the...

Page 16: ...ttings Sensor system Light 1 3 operation Drive 1 3 operation Setting depends on the device model or the settings selected Temperature settings Fig 3 Navigation by swiping top menu level Cancel key Go...

Page 17: ...w the device and application version 1 The dots on the lower display edge symbolise the individual menu pages in the main menus The currently selected position is marked in colour Swipe to the left or...

Page 18: ...nfirm and return to the previous menu level after saving from the settings screens Display brightness Tap on the brightness symbol to call up the display brightness settings 1 Tap on the left part of...

Page 19: ...r the period set in the ETS Screen is switched off after the period set in the ETS Screen saver not active 2 The navigation bar keys take you back to the start page or let you confirm the changes with...

Page 20: ...t right arrow keys The name of the menu and the symbol are displayed Settings Sensor system measured value display Light 1 3 Drive 1 3 Only those menus are shown that have been activated for display i...

Page 21: ...setting The wait time for the switch is pre set in the ETS see chapter Display page 45 2 The navigation bar keys take you back to the start page or allow you to confirm the changes with OK 5 2 2 Butt...

Page 22: ...symbol to show the device version 1 This shows the software version and the application version VD or KNXprod file that is needed for the device 2 The navigation bar touch keys allow you to cancel an...

Page 23: ...us The relative air humidity is displayed in The CO2 content in the air is shown in ppm parts per million with 1000 ppm 0 1 CO2 levels between 300 ppm and 1000 ppm are referred to as fresh air From 10...

Page 24: ...f the nominal value is blocked in one mode the sym bol Manual blocked is briefly shown when an attempt is made to modify the value 3 Tapping on the mode symbol displays the temperature control modes t...

Page 25: ...when having guests The duration of this comfort extension pe riod is set in the ETS The remaining time is shown next to the symbol After the com fort extension period is terminated the system returns...

Page 26: ...es i e the dimming increases in brightness or de creases alternately 3 The dots on the lower display edge symbolise the individual menu pages in the main menus The currently selected position is marke...

Page 27: ...he lamp in percent 4 The dots on the lower display edge symbolise the individual menu pages in the main menus The currently selected position is marked in colour Swipe to the left or right in the top...

Page 28: ...fort dead man can be set in the ETS Drive 1 3 page 50 The slide bar allows you to quickly adjust the movement position This change does not influence the slat position of slat shutters The slide bar p...

Page 29: ...Input WCT 19 001 DPT_ DateTime 8 bytes 22 Date Input WCT 11 1 DPT_Date 3 bytes 23 Time Input WCT 10 1 DPT_ TimeOfDay 3 bytes 25 Screen brightness in Input RWC 5 1 DPT_Scaling 1 byte 26 Screen save 1...

Page 30: ...Drive 1 slat position Input WCT 5 1 DPT_Scaling 1 byte 48 Drive 2 long term Output CT 1 8 DPT_Up Down 1 bit 49 Drive 2 short term Output CT 1 8 DPT_Up Down 1 bit 50 Drive 2 movement position Input Out...

Page 31: ...1 1 DPT_Switch 1 bit 76 Temp threshold value 1 Switching output block Input WC 1 1 DPT_Switch 1 bit 78 Temp threshold value 2 Absolute value Input Output RWCT 9 1 DPT_Val ue_Temp 2 bytes 79 Temp thres...

Page 32: ...protection activation Input RWCT 1 1 DPT_Switch 1 bit 104 Temp controller Block 1 Blocking Input WC 1 1 DPT_Switch 1 bit 105 Temp controller Current setpoint Output R CT 9 1 DPT_Val ue_Temp 2 bytes 10...

Page 33: ...0 OFF Output R CT 1 1 DPT_Switch 1 bit 126 Temp controller Status heating level 2 1 ON 0 OFF Output R CT 1 1 DPT_Switch 1 bit 127 Temp controller Status cooling level 1 1 ON 0 OFF Output R CT 1 1 DPT_...

Page 34: ...dSec 2 bytes 185 Humidity threshold value 1 Switching output Output R CT 1 1 DPT_Switch 1 bit 186 Humidity threshold value 1 Switching output block Input WC 1 1 DPT_Switch 1 bit 187 Humidity threshold...

Page 35: ...Output R CT 9 1 DPT_Val ue_Temp 2 bytes 223 Coolant temp Actual value Input RWCT 9 1 DPT_Val ue_Temp 2 bytes 224 Coolant temp Offset change 1 0 Input WC 1 1 DPT_Switch 1 bit 225 Coolant temp Offset c...

Page 36: ...PT_Switch 1 bit 259 Humidity controller Humidification status 1 ON 0 OFF Output R CT 1 1 DPT_Switch 1 bit CO2 sensor objects 291 328 for Cala KNX AQS TH item no 70603 70608 291 CO2 sensor Malfunction...

Page 37: ...value 3 Delay from 0 to 1 Input WC 7 005 DPT_ TimePeriodSec 2 bytes 313 CO2 threshold value 3 Delay from 1 to 0 Input WC 7 005 DPT_ TimePeriodSec 2 bytes 314 CO2 threshold value 3 Switching output Out...

Page 38: ...actuating variable Output Output R CT 5 1 DPT_Scaling 1 byte 367 Comparator 1 actuating variable Block 1 block Output WC 1 2 DPT_Bool 1 bit 368 Comparator 2 actuating variable Input 1 Input WC 5 1 DPT...

Page 39: ...DPT_Scaling 1 byte 388 Comparator 4 actuating variable Block 1 block Output WC 1 2 DPT_Bool 1 bit Computer multi function modules objects 401 463 for all models 401 Computer 1 Input I1 Input RWCT Dep...

Page 40: ...oring status Output R CT 1 1 DPT_Switch 1 bit 424 Computer 3 Block 1 block Input WC 1 1 DPT_Switch 1 bit 425 Computer 4 Input I1 Input RWCT Depending on setting 4 bytes 426 Computer 4 Input I2 Input R...

Page 41: ...block Input WC 1 1 DPT_Switch 1 bit 449 Computer 7 Input I1 Input RWCT Depending on setting 4 bytes 450 Computer 7 Input I2 Input RWCT Depending on setting 4 bytes 451 Computer 7 Input I3 Input RWCT D...

Page 42: ...ool 1 bit 495 Logic input 15 Input WC 1 2 DPT_Bool 1 bit 496 Logic input 16 Input WC 1 2 DPT_Bool 1 bit 501 AND logic 1 1 bit switching output Output R CT 1 2 DPT_Bool 1 bit 502 AND logic 1 8 bit outp...

Page 43: ...te 527 AND logic 7 8 bit output B Output R CT 5 010 DPT_Val ue_1_Ucount 1 byte 528 AND logic 7 Block Input WC 1 1 DPT_Switch 1 bit 529 AND logic 8 1 bit switching output Output R CT 1 2 DPT_Bool 1 bit...

Page 44: ...l ue_1_Ucount 1 byte 555 OR logic 6 8 bit output B Output R CT 5 010 DPT_Val ue_1_Ucount 1 byte 556 OR logic 6 Block Input WC 1 1 DPT_Switch 1 bit 557 OR logic 7 1 bit switching output Output R CT 1 2...

Page 45: ...5 10 DPT_Val ue_1_Ucount 1 byte 597 Push button 2 encoder 16 bit Output R CT 9 9 xxx 2 bytes 598 Button 2 Scene call up Output R CT 18 001 DPT_SceneCon trol 1 byte 599 Button 2 NTC measured value Out...

Page 46: ...tton 4 switching Output R CT 1 1 DPT_Switch 1 bit 617 Push button 4 dimming Input Output RWCT 3 7 DPT_Con trol_Dimming 4 bit 618 Push button 4 encoder 8 bit Output R CT 5 10 DPT_Val ue_1_Ucount 1 byte...

Page 47: ...after the reset In addition set whether the time and date are to be received as separate objects or as one common object If time and date are received via two objects then only a maxi mum of 10 second...

Page 48: ...man and English as display languages Select the type of screen saver clock or black screen or deactivate the screen saver inactive Then select whether the display is to jump to the start page if the s...

Page 49: ...e setting after voltage return and programming for first commissioning Switch the tone on or off Display The possible settings on the device display are explained in the chapter Device control on the...

Page 50: ...on the device display are explained in the chapter Device control on the touch display Sensor system measured value display page 20 7 5 3 Temperature control The temperature control menu is connected...

Page 51: ...reas and whether the lamp can be dimmed Select the symbol shown Determine the period of time between switching and dimming for all control types with dimming Short tapping means a switch command If th...

Page 52: ...rve chapter Control modes for drive control page 63 The possible settings on the device display are explained in the chapter Device control on the touch display Drive shading window page 25 7 6 Variab...

Page 53: ...Maximum value Minimum value Average value Use input 1 2 3 4 5 No Yes Output sends on change of output on change of output and periodically when receiving an input object when receiving an input object...

Page 54: ...E2 Amount Calculation Output 1 E1 X Y Output 2 E2 X Y Transformation General Tolerance for comparison in the case of prerequisite E1 E2 0 4 294 967 295 Input type Selection options depending on the fu...

Page 55: ...ked 0 Input range depending on the type of output Output sends on change on change and after reset on change and periodically when receiving an input object when receiving an input object and periodic...

Page 56: ...set what a 1 or 0 at the block entry means and what happens in the event of a block Output sends on change on change and after reset on change and periodically when receiving an input object when rece...

Page 57: ...tions are available for AND and OR logic Each logic output may transmit one 1 bit or two 8 bit objects Determine what the out put should send if logic 1 and 0 Value before first call 0 1 Output patter...

Page 58: ...t two 8 bit objects Output value if logic 1 1 0 Output value if logic 0 1 0 Output value If block is active 1 0 Output value if monitoring period is exceeded 1 0 Object type Value 0 255 Percent 0 100...

Page 59: ...of logic to 0 on change of logic and periodically on change of logic to 1 and periodically on change of logic to 0 and periodically on change of logic object receipt on change of logic object receipt...

Page 60: ...ed Logic input 12 Logic input 12 inverted Logic input 13 Logic input 13 inverted Logic input 14 Logic input 14 inverted Logic input 15 Logic input 15 inverted Logic input 16 Logic input 16 inverted Fo...

Page 61: ...itching output 2 Humidity Switching output 2 Humidity inverted Switching output 3 Humidity Switching output 3 Humidity inverted Switching output 4 Humidity Switching output 4 Humidity inverted Switchi...

Page 62: ...rted Switching output AND logic 4 Switching output AND logic 4 inverted Switching output AND logic 5 Switching output AND logic 5 inverted Switching output AND logic 6 Switching output AND logic 6 inv...

Page 63: ...the bus function shutter awning blinds or window and specify the button function and control mode Bus function Switch Command when pressing the button send 0 send 1 do not send telegram Command when...

Page 64: ...oder bus function and specify which value will be sent Input for scenario control If the input is to be used for recalling and saving a scene select the bus function scene call up and decide whether t...

Page 65: ...y or stops If operated longer the drive will move up to the end position The time difference between short and long is set individually Bus function Temperature sensor NTC Use malfunction object Yes N...

Page 66: ...eleasing the but ton If the drive must be moved independently into the end position the button is released only after times 1 2 have expired The move can be stopped by briefly pushing Control mode Sta...

Page 67: ...l changes and errors excepted Dead man s switch The drive moves as soon as the button is pushed and stops as soon as the button is released Time 1 0 0s 2 s 0 4 s Time 2 0 s 2 s 2 s Control mode Dead m...

Page 68: ...nt to the bus Use the Reset temperature min max value objects to reset the values to the current readings The values are not retained after a reset 8 2 Temperature threshold values Activate the requir...

Page 69: ...service the last communicated threshold value can be used Basically a temperature range is given in which the threshold value can be changed object val ue limit A set threshold value will be retained...

Page 70: ...0 TV hyst above 1 Delays can be set via objects in seconds No Yes Switching delay from 0 to 1 If delay can be set via objects valid until 1st communication None 1 s 2 s 5 s 10 s 2 h Switching delay f...

Page 71: ...he temperature control include the setpoint temperatures for the in dividual modes Objects are used to determine which mode is to be selected A change of mode may be triggered manually or automaticall...

Page 72: ...c sending is safer in case a message does not reach a recipient You may also set up periodical monitoring by the actuator with this setting The status object reports the current status of the control...

Page 73: ...trol may be reset to comfort mode from eco mode which is used as night mode via the comfort extension This allows the user to maintain the comfort setpoint value for a longer time e g when having gues...

Page 74: ...etpoint Standby mode is usually used for daytime mode when people are absent If setpoint values are entered separately A starting setpoint value is defined as well as a temperature range in which the...

Page 75: ...ooling are determined which may not be modified from outside no access via operating devices etc The building protection mode may be activated with delay which allows you to leave the building before...

Page 76: ...two levels must also be specified i e be low which setpoint deviation the second level is added PI control with control parameters This setting allows individual input of the parameters for PI control...

Page 77: ...trol is blocked Set a value greater 0 OFF to receive a basic heating level e g for floor heating On release the control variable follows the rule again In case of a common control variable for heating...

Page 78: ...hould be sent when the control is blocked Set a value greater 0 OFF to receive a basic heating level e g for floor heating On release the control variable follows the rule again 8 3 2 Cooling control...

Page 79: ...opriate to the cooling system at this point observe manufacturer s instructions Now specify what should be sent when the control is blocked On release the control variable follows the rule again In ca...

Page 80: ...on control variable for heating and cooling 0 is always transmitted as a fixed value 8 4 Summer Compensation With the summer compensation the target value for the room temperature can auto matically b...

Page 81: ...ensation and set what a 1 or 0 at the block input means and what happens in the event of a block Use summer compensation No Yes Characteristic curve description External temperature point 1 in 0 1 C i...

Page 82: ...etc are related to the overall reading The minimum and maximum readings can be saved and sent to the bus Use the Reset humidity min max value objects to reset the values to the current readings The v...

Page 83: ...ease During initial commissioning a threshold value must be defined which will be valid until the first communication with a new threshold value For units which have already been taken into service th...

Page 84: ...s TV Threshold value TV above 1 TV hyst below 0 TV above 0 TV hyst below 1 TV below 1 TV hyst above 0 TV below 0 TV hyst above 1 Delays can be set via objects in seconds No Yes Switching delay from 0...

Page 85: ...y also set up periodic monitoring using an actuator with this setting On release with 2 seconds release delay Dependent on the Switching output sends setting Switching output sends on change Do not se...

Page 86: ...which the setpoint value can be changed object value limit Enter how the setpoint value will be received from the bus Basically a new value can be received or simply a command to increase or decrease...

Page 87: ...y the controller responds to deviations from the set point value In case of a short reset time the control responds with a fast increase of the control variable In case of a long reset time the contro...

Page 88: ...hreshold value dewpoint temperature offset Set in which cases offset received via object is to be retained Please note that the set ting After power supply restoration and programming should not be us...

Page 89: ...at absolute setting 0 1000 50 Threshold value sends never periodically on change on change and periodically At and above change of if sent on change 0 1 C 0 2 C 0 5 C 1 0 C 2 0 C 5 0 C Send cycle if...

Page 90: ...aviour of the switching output On block Do not send message send 0 send 1 On release with 2 seconds release delay Dependent on the Switching output sends setting Switching output sends on change Do no...

Page 91: ...er ature and humidity The specified standard values comply with DIN 1946 Temperature hysteresis 1 C Relative humidity hysteresis 2 RH Absolute humidity hysteresis 2 g kg Use comfort field No Yes Sendi...

Page 92: ...all reading The maximum reading can be saved and sent to the bus Using the Reset CO2 max imum value objects the value can be reset to the current reading The value is not re tained after a reset 10 2...

Page 93: ...e During initial commissioning a threshold value must be defined which will be valid until the first communication of a new threshold value For units which have already been taken into service the las...

Page 94: ...hold value TV above 1 TV hyst below 0 TV above 0 TV hyst below 1 TV below 1 TV hyst above 0 TV below 0 TV hyst above 1 Delays can be set via objects in seconds No Yes Switching delay from 0 to 1 If de...

Page 95: ...ator with this setting On release with 2 seconds release delay Dependent on the Switching output sends setting Switching output sends on change Do not send message Send switching output status Switchi...

Page 96: ...ated setpoint value can be used Basically an air humid ity range is given in which the setpoint value can be changed object value limit A set setpoint value will be retained until a new value or a cha...

Page 97: ...onds with a fast increase of the control variable In case of a long reset time the control responds somewhat less urgently and needs longer until the necessary control variable for the setpoint value...

Page 98: ...bH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de Technical support 49...

Reviews: