![ELSA LANCOM Business 6000 Manual Download Page 36](http://html1.mh-extra.com/html/elsa/lancom-business-6000/lancom-business-6000_manual_2396405036.webp)
Configuration and management
|
|
ELSA LANCOM Business 6000
|
36
EN
Any appended parameters are processed from left to right. This means that
it is possible to call a parameter and then restrict it.
Examples
IP-masquerading
Processes in the masquerading module
DHCP
Dynamic Host Configuration Protocol
D channel
Trace on the D channel of the connected ISDN bus
This combination
command...
... brings up the following display for the trace:
All
All trace outputs
Display
Status and error outputs
Protocol
ELSA and PPP outputs
TCP-IP
IP-Rt., IP-RIP, ICMP and ARP outputs
IPX-SPX
IPX-Rt., RIP, SAP, IPX-Wd., SPX-Wd., and NetBIOS outputs
Time
Displays the system time in front of the actual trace output
Source
Includes a display of the protocol that has initiated the output in
front of the trace
This code...
... in combination with the trace causes the following:
trace
Displays all protocols that can generate outputs during the confi-
guration, and the status of each output (ON or OFF).
trace + all
Switches on all trace outputs
trace + protocol dis-
play
Switches on the output for all connection protocols together with
the status and error messages
trace + all - icmp
Switches on all trace outputs with the exception of the ICMP pro-
tocol
trace ppp
Displays the status of the PPP
trace # ipx-rt
display
Toggles between the trace outputs for the IPX router and the dis-
play outputs
trace - time
Switches off the system time output before the actual trace output
This parameter...
... brings up the following display for the trace:
Summary of Contents for LANCOM Business 6000
Page 1: ...ELSA LANCOM TM Business 6000...
Page 4: ...ELSA LANCOM Business 6000 EN...
Page 10: ...Introduction ELSA LANCOM Business 6000 10 EN...
Page 52: ...Connection via 2 Mbit interface ELSA LANCOM Business 6000 52 EN...
Page 110: ...Operating modes and functions ELSA LANCOM Business 6000 110 EN...
Page 162: ...Technical data ELSA LANCOM Business 6000 162 EN...