Elnec s. r. o.
68
Checkbox
Set Protected mode of software after loading of this project file
is used to
save project in special mode called Protected mode. After clicking the button with key,
password dialog appears, which is used to specify Protected mode password for project
being saved, and another security options (disable other project loading, device operations
restriction) to prevent operator's mistakes. Projects saved with active
Protected mode
are
special projects called
Protected mode projects
. For more detailed information about
Protected mode projects see
Options / Protected mode
. When Protected mode is active,
the software indicates this by
label Protected mode
in right top corner of Programmer
activity log.
Recommendation: passwords for Encrypt project file (with password) and Set Protected
mode of software after loading of this project file should not be the same.
Checkbox
Require project file checksum before first programming
when active, software
asks user for entering correct project file unique ID, before allowing to start the first device
programming after load project. This feature is recommended for additional check, that
correct project file is recently loaded. There is also recommended using this checkbox along
with active
Protected mode
. When the request of project file unique ID is active, the software
indicates this by label (
ID)
next to project file name in bottom status line in control program
main window.
Note: Option Require project file unique ID before first programming is replacement of former
Require project file checksum before first programming. Unique ID advantage over generic
checksum is that unique ID is calculated not just from main device buffer data, but also from
secondary buffers data used by device and available device settings. When the request of
project file checksum is active, the software indicates this by label (CSum) next to project file
name in bottom status line in control program main window. This option is no longer available
in Save project dialog, but it can be activated after loading of older project file, that has the
checksum request set on.
File / Reload file
Choose this option to reload a recently used file.
When you use a file, it is added to the
Reload file
list. Files are listed in order depending on
time of use of them. Lastly used files are listed before files used far off.
To Reload a file:
1. From the File menu, choose Reload file.
2. List of lastly used files is displayed. Click the file you want to reload.
Note: When reloading a file the file format is used, by which the file was lastly loaded/saved.
File / Reload project
Choose this option to reload a recently used project.
When you use a project, it is added to the
Reload project
list. Projects are listed in order
depending on time of use of them. Lastly used projects are listed before projects used far off.
To Reload a project:
Summary of Contents for BeeHive304
Page 6: ...Elnec s r o 6 Introduction ...
Page 10: ...Elnec s r o 10 Quick Start ...
Page 13: ...Detailed description 13 Detailed description ...
Page 14: ...Elnec s r o 14 BeeHive304 ...
Page 29: ...BeeProg3 29 BeeProg3 ...
Page 43: ...Setup 43 Setup ...
Page 58: ...Elnec s r o 58 PG4UW software ...
Page 125: ...PG4UWMC software 125 PG4UWMC software ...
Page 138: ...Elnec s r o 138 Installation procedure customized ...
Page 143: ...Common notes 143 Common notes ...
Page 148: ...Elnec s r o 148 Troubleshooting and warranty ...
Page 152: ...Elnec s r o Jana Bottu 5 SK 080 01 Presov Slovakia www elnec com ZLI 0330 ...