Elnec s. r. o.
120
Multi-project Wizard
Multi-project device operation requires Multi-project file, which contains partial sub-projects
associated to sub-devices (chips) of Master device. Multi-project file can be created in Multi-
project Wizard. The Wizard has following main functions:
Select of sub-projects and build final Multi-project file
Load of existing Multi-project file *1
Start device operation of recent Multi-project
Note *1: Existing Multi-project file can be loaded from main menu of PG4UW using menu
File / Load project or from Multi-project Wizard by Load multi-prj command.
Multi-project Wizard contains following controls:
Button
Load multi-prj
is used for load of existing Multi-project file.
Button
Build Multi-project
is used for build of new Multi-project file, which uses projects
listed in table Sub-projects.
Table 1: Sub-projects
contains list of projects that are included in recent Multi-project.
Button
Add project
is used for adding of new project file(s) to list of project files in Table1.
Button
Remove project
is used for removing of selected project file from list of project
files in Table 1.
Buttons
Move up a Move down
are used for moving of selected project in Table 1 one
position up or down. Projects are processed in specified sequence order, the upper-most
(#1) as first.
Button
Help
show this help.
Buttons of device operation
Blank, Verify, Program, Erase, or Run
are used for running
of selected device operation on all chips (sub-devices) listed in table Sub-projects.
In
"Multi operation" mode
, one of all available operations can be run at a time (the
same operation on each sub-device).
In
"One operation" mode
, only one operation can be run (the same operation on each
sub-device) or each subproject can run it's own (one) operation, depending on projects
the Multi-project consists of.
Following two basic actions have to be performed when using Multi-project to program
Multi-chip devices (similar also for Single-chip devices)::
Making (building) of Multi-project (or Multi-project file)
Using of Multi-project for running of device operation
Making (building) of Multi-project (or Multi-project file)
Following steps are recommended when making Multi-project file:
Create "classic" projects, one project for each sub-device of multichip device.
Projects are created in the same way as projects for generic devices:
select sub-device according to required chip of multichip device *1
set device parameters, settings, and load required device data to buffer by Load file
command in PG4UW
optionally make test of device operation by running the device operation on device
if everything is OK, the project file can be created by Save project command
Select Master multichip device, the Multi-project has to be used for. After selection of
multichip device, Multi-project Wizard is automatically opened.
Summary of Contents for BeeHive304
Page 6: ...Elnec s r o 6 Introduction ...
Page 10: ...Elnec s r o 10 Quick Start ...
Page 13: ...Detailed description 13 Detailed description ...
Page 14: ...Elnec s r o 14 BeeHive304 ...
Page 29: ...BeeProg3 29 BeeProg3 ...
Page 43: ...Setup 43 Setup ...
Page 58: ...Elnec s r o 58 PG4UW software ...
Page 125: ...PG4UWMC software 125 PG4UWMC software ...
Page 138: ...Elnec s r o 138 Installation procedure customized ...
Page 143: ...Common notes 143 Common notes ...
Page 148: ...Elnec s r o 148 Troubleshooting and warranty ...
Page 152: ...Elnec s r o Jana Bottu 5 SK 080 01 Presov Slovakia www elnec com ZLI 0330 ...