#xx5 - bad length of current line
#xx6 - too big negative offset
#xx7 - address is out of buffer range
#xx8 - bad type of selected file format
#xx9 - the file wasn't loaded all
File / Save
This command saves data in the buffer which has been created, modified or read from a
device onto a specified disk. The file format of saved file can be chosen from supported
formats list box. There can be also entered the Buffer start and Buffer end addresses which
exactly specify part of buffer to save to file. Supported file formats now are
binary
,
MOTOROLA
,
MOS Technology
,
Tektronix
,
Intel (extended) HEX
,
ASCII space
,
JEDEC
and
POF
.
If the checkbox
Swap bytes
is displayed, the user can activate function of swapping bytes
within 16bit words (or 2-byte words) during writing to file. This feature is useful especially
when saving files with Motorola representation of byte order in file (big endian). Standard
save file operation is using little endian byte order.
The reserved key
<F2>
will bring out this menu from any menu and any time.
File / Load project
This option is used for loading project file, which contains device configuration buffer data
saved and user interface configuration.
The standard dialog
Load project
contains additional window -
Project description
- placed
at the bottom of dialog. This window is for displaying information about currently selected
project file in dialog Load project.
Project information consists of:
manufacturer and name of the first device selected in the project
date and time of project creation
user written description of project (it can be arbitrary text, usually author of project and
some notes)
Note: for projects with serialization turned on
Serialization is read from project file by following procedure:
1. Serialization settings from project are accepted
2. Additional serialization file search is performed. If the file is found it will be read and
serialization settings from the additional file will be accepted. Additional serialization file
is always associated to the specific project file. When additional serialization file settings
are accepted, project serialization settings are ignored.
Name of additional serialization file is derived from project file name by adding extension ".sn"
to project file's name.
Additional serialization file is always placed to the directory "serialization\" into the control
program's directory.
Summary of Contents for BeeHive304
Page 6: ...Elnec s r o 6 Introduction ...
Page 10: ...Elnec s r o 10 Quick Start ...
Page 13: ...Detailed description 13 Detailed description ...
Page 14: ...Elnec s r o 14 BeeHive304 ...
Page 29: ...BeeProg3 29 BeeProg3 ...
Page 43: ...Setup 43 Setup ...
Page 58: ...Elnec s r o 58 PG4UW software ...
Page 125: ...PG4UWMC software 125 PG4UWMC software ...
Page 138: ...Elnec s r o 138 Installation procedure customized ...
Page 143: ...Common notes 143 Common notes ...
Page 148: ...Elnec s r o 148 Troubleshooting and warranty ...
Page 152: ...Elnec s r o Jana Bottu 5 SK 080 01 Presov Slovakia www elnec com ZLI 0330 ...