PG4UW software
109
If the program detects removal of a device, then status LED will switched off, but the BUSY
LED will still blinking to indicate readiness of the program to repeat last operation with new
device.
After the program indicates one or more pins of (new) device in the ZIF socket, the BUSY
LED will goes to light continually. From this the program will wait a requested time for insert
the rest pins of new device. If a requested time (Device insertion complete time) overflows
and a device is not correctly inserted, the program will light the ERROR LED to indicate this
state. After new device was inserted correctly, the program will switch off all status LEDs,
except BUSY, and will start an operation with new device.
This mode may be enabled or disabled by item
Automatic YES!
mode. If a new programmer
is selected
Options / Find programmer
, this mode will be disabled.
The
Response time
is interval between insertion of the chip into the ZIF socket and the start
of selected device operation. If longer positioning of the chip in the ZIF socket is necessary
select
elongated
response time.
Programming adapter used
shows name of adapter used with currently selected device.
Pins of ZIF socket excluded from sensing
contains list of pins that will be ignored from
testing by Automatic YES!. The reason to ignore the pins is mostly - capacitors connected to
these pins.
Button
Setting Automatic YES! parameters
will run wizard that can detect permanently
connected pins (pins with capacitors) and set these pins to list of pins excluded from sensing.
After selecting of device, list of excluded pins contains default excluded pins for selected
device adapter. If other bypass capacitors to universal programmer and/or device adapter are
added by customer, there is necessary to run
Automatic YES! parameters wizard
to
override default parameters and detect other pins with capacitors.
In
Device removal hold off time
is time period between you removed device from the ZIF
socket and the time when software starts to check the socket for new device inserted. This
interval is in seconds and must be from 1 to 120 (default value is 2 seconds).
In
Device insertion complete time
is possible to set a time within all pins of the device have
to be properly inserted after a first pin(s) detected so that the program will not detects
incorrectly inserted device. This interval is in seconds and must be from 1 to 120 (default
value is 5 seconds).
The
Suspend on error
defines if the Automatic YES! function will be temporary disabled on
error to see result of operation or will going on without suspension.
The options are set to defaults after new device is selected by
Device / Select device
This setting is saved to disk by command
Options / Save options
and could be saved into
the project file for selected device File / Save project ...
Note: When using device socket adapters with some passive or active parts, for example
capacitors for bypassing supply voltage, the Automatic YES! function may need to set these
pins to Pins with capacitors list. This is necessary to make Automatic YES! function working
properly. Otherwise Automatic YES! function will "think" the pins are still connected and it will
not allow user to insert new device and start new programming.
Summary of Contents for BeeHive304
Page 6: ...Elnec s r o 6 Introduction ...
Page 10: ...Elnec s r o 10 Quick Start ...
Page 13: ...Detailed description 13 Detailed description ...
Page 14: ...Elnec s r o 14 BeeHive304 ...
Page 29: ...BeeProg3 29 BeeProg3 ...
Page 43: ...Setup 43 Setup ...
Page 58: ...Elnec s r o 58 PG4UW software ...
Page 125: ...PG4UWMC software 125 PG4UWMC software ...
Page 138: ...Elnec s r o 138 Installation procedure customized ...
Page 143: ...Common notes 143 Common notes ...
Page 148: ...Elnec s r o 148 Troubleshooting and warranty ...
Page 152: ...Elnec s r o Jana Bottu 5 SK 080 01 Presov Slovakia www elnec com ZLI 0330 ...