PG4UWMC software
135
Device removal hold off time
- time period between you removed device from the ZIF
socket and the time when software starts to check the socket for new device inserted. This
time is in seconds and must be from 1 to 120 (default value is 2 seconds).
Device insertion complete time
- time within all pins of the device have to be properly
inserted after a first pin(s) detected so that the program will not detects incorrectly inserted
device. This interval is in seconds and must be from 1 to 120 (default value is 5 seconds).
Suspend on error
- defines if the Automatic YES! function will be temporary disabled on
error to see result of operation or will going on without suspension.
Indication of state when software waits for a new device:
Not indicated (quiet mode)
- the programmer, regardless of the number of ZIF, does not
indicate the state when a device is programmed and the programmer with software wait for
inserting a new device. After an operation with a device only one of the status LEDs Error or
OK lights, in dependence on the result of previous operation. This LED goes off immediately
after detecting removal of a device from the ZIF socket.
By LED Busy blinking
- the programmer, regardless of the number of ZIF sockets, indicates
the state when a device is programmed and the programmer with software wait for inserting a
new device mode by blinking with the LED Busy. After an operation with a device is done,
one of the status LEDs (OK or Error) lights, in dependence on the result of previous operation
and the LED Busy is blinking. If the program detects removal of a device from ZIF socket,
then the status LED goes off, but the LED Busy is still blinking to indicate readiness of the
program to repeat last operation with new device. After the program indicates one or more
pins of (new) device in the ZIF socket, the LED Busy goes light continually. From this point
the program waits a requested time for insertion of the rest pins of new device. If a requested
time (Device insertion complete time) overflows and a device is not correctly inserted, the
program will light the LED Error to indicate this state. When new device is inserted correctly,
the status LED goes off and a new operation with device is started.
Enable sound when ready for a new device
- when checked, sound will be generated if SW
detects complete empty ZIF socket and is ready to accept new device into ZIF socket.
When any of previous options is selected and confirmed by OK button, PG4UWMC send
selected settings to all connected programming site. Also if you set Automatic YES!
parameters on master programming site these settings will be send to all connected slave
programming site sites and to PG4UWMC.
For more details about Automatic YES! feature see Programmer / Automatic YES!.
Other
Colors of the work result LEDs of programmer:
Standard LED color scheme (ERROR=red, BUSY=yellow)
Former LED color scheme (ERROR=yellow, BUSY=red)
Note: These settings are available only for some types of programmers. If you can't see
mentioned settings in menu, or menu is not enabled for editing, your programmer doesn't
support LED color scheme customization.
Summary of Contents for BeeHive304
Page 6: ...Elnec s r o 6 Introduction ...
Page 10: ...Elnec s r o 10 Quick Start ...
Page 13: ...Detailed description 13 Detailed description ...
Page 14: ...Elnec s r o 14 BeeHive304 ...
Page 29: ...BeeProg3 29 BeeProg3 ...
Page 43: ...Setup 43 Setup ...
Page 58: ...Elnec s r o 58 PG4UW software ...
Page 125: ...PG4UWMC software 125 PG4UWMC software ...
Page 138: ...Elnec s r o 138 Installation procedure customized ...
Page 143: ...Common notes 143 Common notes ...
Page 148: ...Elnec s r o 148 Troubleshooting and warranty ...
Page 152: ...Elnec s r o Jana Bottu 5 SK 080 01 Presov Slovakia www elnec com ZLI 0330 ...