10.3.1.3.
Hall Sensors
Figure 29: Hall Sensors Connection Diagram
For short distances between the drive and control, 0.5 to 1.0 m wires can be used and shielding
is not required.
For longer distances than 1.0 m and/or high EMI environment, shielded and
twisted wires should be used. Drain wires should be connected to Elmo COMRET.