M1G Installation and Programming
Page 31
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
ZN001 02:Type=0
r
0=EOL Supervised
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
12345678901234567890123456789012123
ZN001 03:Area=1
r
[Area Name]
Wiring configuration for HARDWIRED zones. Burglar and Keyswitch zones may be set to:
0, 1, 2, 3, & 4. Other non-fire zones may be set to: 0, 1 or 2 only. Fire zones may be
5=EOL Supervised 4-wire detectors, 6=EOL Supervised 2-wire detectors (zone 16 ONLY!)
Enter the area (partition) number that this zone is to be assigned to. A zone can only
reside in one area and fire zones can only reside in Area 1.
Menu 05 - Zone Definitions
(continued)
15
†
Keyfob
- Used when a wireless keyfob is enrolled into a receiver at this zone ID location.
16
Non Alarm -
Intended for use in Whenever/And/Then rules from the Remote Programming RP software. This zone
type DOES NOT ACTIVATE any alarm and is not logged in the Event log. No reset is required.
17
††
Carbon Monoxide 24 hr
- Activates an immediate Carbon Monoxide alarm if tripped anytime (armed or
disarmed). The keypad will display the alarm as well as the event log. This type of alarm can be silenced/reset
with a valid User Code. The audible alarm can be set in “Cutoff Timers”.
18
Emergency 24 hr
- Similar to Def 17, this zone creates an alarm if tripped anytime (armed or disarmed).
19
††
Freeze Alarm 24 hr
- Similar to Def 17, this zone creates an alarm if tripped anytime (armed or disarmed).
20
††
Gas Alarm 24 hr
- Similar to Def 17, this zone creates an alarm if tripped anytime (armed or disarmed).
21
††
Heat Alarm 24 hr
- Similar to Def 17, this zone creates an alarm if tripped anytime (armed or disarmed).
22
Medical Alarm 24 hr
- Activates an immediate Medical alarm if tripped anytime (armed or disarmed).
23
Police Alarm w/Indication 24 hr
- Activates an audible Police (Holdup) alarm if tripped (armed or disarmed).
24
Police Alarm no Indication 24 hr
- Activates an non-audible Police (Silent) alarm if tripped (armed or disarmed).
25
††
Water Alarm 24 hr
- Activates an immediate Water alarm if tripped anytime (armed or disarmed).
26
Keyswitch Momentary
- Intended for a spring loaded momentary key switch. Toggles the armed state (disarmed/
armed) with each trip.
27
Keyswitch Momentary - Away Mode
- Intended for a spring loaded momentary key switch. Arms the area in the
AWAY mode with each trip.
28
Keyswitch Momentary - Stay Mode
- Intended for a spring loaded momentary key switch. Arms the area in the
STAY mode with each trip.
29
Keyswitch Momentary - Disarm Only
- For a spring loaded momentary key switch. Disarms with each trip.
30
Keyswitch On/Off (Maintained)
- Intended for a 2 position On/Off key switch. Arms the area in Open position.
Disarms the area in the Closed position.
31
††
Mute All Area Audibles
- For silencing all area audibles by a two-way listen-in module (other manufacturer).
32
Power Supervisory 24 hr
- For supervising an external power supply which provides alarm/trouble contacts. Wire
the power supply contacts to open the zone in a Low Battery event and short the zone in an AC Failure event.
33
†
Temperature
- For use with ELK-M1ZTS Temperature Sensors. Requires the use of Whenever/And/Then rules
from the ELK-RP software.
NOTE: This definition is for ZONES 1 thru 16 ONLY! Temperature zones must be set
to FAST LOOP (less that 200ms) response.
34
†
Analog
- For sensors that produce a variable voltage (0 to 12 volt range). Requires the Whenever/And/Then
rules from the ELK-RP software.
NOTE: This definition is only available with the ELK-M1G (Gold) control.
Def Zone Description
Operating Characteristics
0
EOL Supervised.
EOL resistor is 2,200 Ohms * Type 0 is the factory default for all zones including wireless. While
disarmed a violation will occur if the hardwire loop opens or shorts, or the wireless sensor is opened or tampered.
NOTE
: For UL Tamper Supervision with ELK-M1XRFTW wireless burglary sensors, Zone Type 4 (see below) shall be
used to provide daytime tamper (disarmed) notification from the wireless sensor.
1
Normally Closed only
. No resistor required.
2
Normally Open only
. No resistor required.
3
EOL Supervised with SECURITY ALERT on Short
.
[Burglar & Keyswitch Zones Only)
While disarmed a Security
“Day” Alert will occur if the zone wiring is SHORTED. Keypads will beep and display Security Alert and the zone
number/name. Pressing Star key silences the keypad. A user code must be entered to reset/acknowledge the alert.
While armed an alarm will occur regardless of whether the zone wiring is OPENED or SHORTED.
4
Four (4) State EOL Supervised with SECURITY ALERT on Open or Short.
[Burglar & Keyswitch Zones Only)
Four
(4) State EOL provides both alarm notification (armed) and daytime tamper (not armed) notification from a zone. It
utilizes two (2) EOL resistors (1 in series with the loop and 1 in parallel with the alarm contact), and N/C contacts for
alarm and tamper contacts. While disarmed the Zone will be violated (Not Ready) when the alarm contact opens. But
if the tamper contact opens, OR if the zone wiring is open (cut) or shorted the keypads will beep and display Security
Alert and the zone number/name. Pressing Star will silence the keypad. A user code must be entered to reset/
acknowledge the alert. While armed an alarm will occur regardless of what condition (open, short, etc.) occurs to the
loop. This zone type is intended for daytime tamper notification from a zone sensor.
5
Fire, 4-Wire Smoke Detector
with 2,200 Ohm EOL resistor. Trouble on open, alarm on short. (Zones 1 to 16).
6
Fire, 2-wire Smoke Detector
with 820 Ohm EOL resistor. (ZONE 16 ON)
Type
Wiring Configuration
Operating Description
†
Not evaluated by UL
††
Not for use in UL Listed Systems
Four (4) State EOL Supervised REQUIRES M1 Firmware 4.3.5 or higher