2.1 Introduction
The control has factory default programming which make it easy to bench test prior to installation. Terminate all zones with
EOL resistors, then connect a keypad, transformer, and battery. The factory (Master) user code is 3456. This code can
operate all user related features of the system. This section gives an overview of powering up and basic keypad functioning.
2.2 Powering Up (One Keypad)
After all other connections have been made and checked thoroughly, the controls AC transformer and battery may be
connected. The Master Power Switch located on the lower left corner can then be turned. Upon power up the control will
perform self-diagnostics and auto-enroll the first keypad (Keypad Address #1). Any additional keypads or expanders must be
manually enrolled using Installer Level Programming. See “Menu 01 - Bus Module Enrollment”.
NOTE: It is very important to make certain that every keypad, input expander, output expander, or any other data bus
device be assigned a unique data bus address within its type. See “MENU 01 - Bus Module Enrollment” for instructions
on setting keypad and expander addresses.
System Startup on Battery Only
(Ordinarily the control will not startup without AC power)
If AC power is not available (new construction site, etc.) the control may be started on battery ONLY by shorting the two silver
pads (located in the lower left corner of the circuit board) with a small blade screwdriver. This will temporarily bypass the AC
sensing circuit and allow the control to startup. NOTE: The On/Off power switch must be in the On position.
2.3 User Codes and Authorities
The control has 199 user codes plus one installer code. Each user code may be assigned specific authorities as to what it is
allowed to do. The authorities are assigned from the Installer level programming, however the code digits and user names
are assigned from the keypad user menu 6 - Change User Codes. Only a Master authority level code or the Installer code is
allowed to access keypad user menu 6. The User’s Guide contains a description of operations accessible to the user codes.
Control operations accessed by the installer passcode are slightly different.
Factory Default for User Code 1 is: 3 4 5 6 (Master Code)
(1 2 3 4 5 6 if the six digit code option is enabled)
User code may be used for functions in a specific area or system-wide. Some options may be performed at any time, even
while the control is fully or partially armed. The menu system is designed to be next-step-oriented. After a brief explanation of
the options, the user should be able to begin operating the system immediately. For purposes of discussion, the installer and
the end consumer are both considered users, but have different capabilities.
2.4 Installer Program Code and Authorities
The installer code can access all the keypad user menus and has limited arm/disarm privileges. It may be used to arm any
area and disarm any area as long as the area WAS NOT armed by a user code. The Installer code can silence 24hr alarms
or a Burglary alarms in an area that was armed by the installer or in an area that is not armed. The installer code can silence
a trouble condition in a disarmed area. See User’s Guide for a full description of arming and disarming procedures.
Factory Default for the Installer Program Code is: 1 7 2 8 3 9
WARNING! Do Not use 0 0 0 0 0 0 for the Installer Program Code.
This will cause complete lockout of Keypad Installer Level Programming.
Section 2 - Operating the System