User Manual
EM303B General Purpose Inverter
68
F6-27
Upper Limit Frequency of
Wobbulation
Lower Limit Frequency of
Wobbulation
~
Fmax
Hz
40.00
●
219
F6-28
Lower Limit Frequency of
Wobbulation
0.00/0.0
~
Upper Limit Frequency of
Wobbulation
Hz
20.00
●
220
F6-29
Jump Frequency of
Wobbulation
0.00/0.0
~
(Upper Limit Frequency of
Wobbulation - Lower Limit Frequency
of Wobbulation)/2
Hz
5.00
●
221
No.
Function
Range
Unit
Default Type S/N
F6-30
Rising Time of
Wobbulation
0.00
~
600.00
S/min 15.00
●
222
F6-31
Dropping Time of
Wobbulation
0.00
~
600.00
S/min 5.00
●
223
7.1.3
F7 Group: Advanced Parameters of Operation
No.
Function
Range
Unit Default Type S/N
F7-00
Overload Pre-Alarm Control
Ones place
:
Overload pre-alarm detection
0: Detect all the time
1: Detect at constant speed
Tens place: inverter status after
pre-alarming
0: Alarm on, run continuously
1: Delayed stop after alarm
00
〇
224
F7-01
Overload Pre-Alarm Detection
Time
0.00
~
60.00
S
5.00
〇
225
F7-02
Overload Pre-Alarm Detection
Scale
0.00
~
600d.00
%
200.00
〇
226
F7-03
Overload Pre-Alarm Stop Delay
Time
0.00
~
600.00
S
5.00
〇
227
F7-04
Analog ADT Options
0: VS 0.00
~
100.00%
1: IS 0.00
~
100.00%
2: VF 0.00
~
100.00%
3: IF 0.00
~
100.00%
2
〇
228
F7-05
Analog ADT1
0.00
~
100.00
%
20.00
●
229
F7-06
Analog ADT1 Hysteresis
0.00
~
100.00 (Monotonic decreasing
is active)
%
5.00
●
230
F7-07
Analog ADT2
0.00
~
100.00
%
50.00
●
231
F7-08
Analog ADT2 Hysteresis
0.00
~
100.00 (Monotonic decreasing
is active)
%
5.00
●
232
F7-09
Analog ADT3
0.00
~
100.00
%
80.00
●
233
F7-10
Analog ADT3 Hysteresis
0.00
~
100.00 (Monotonic decreasing
is active)
%
5.00
●
234
F7-11
Jog M0 Output Lower Limit
0.00
~
100.00
%
0.00
●
235
F7-12
Jog M0 Output Upper Limit
0.00
~
100.00
%
100.00
●
236
F7-13
Jog M0 Output Gain
0.00
~
300.00
%
95.00
●
237