User Manual
EM303B General Purpose Inverter
122
of F6-00.
C0-21
Output Power
Present output power
kW
C0-22
PID Input
PID setting
C0-23
PID Calculation Feedback
PID feedback
C0-24
Torque Current Input Iq*
Present torque current input setting
value
%
C0-25
Torque Current Feedback Iq
Present output torque current value
%
C0-26
Input Terminal Status
X7 X6 X5 X4 X3 X2 X1
0
0
0
0
0
0
0
X1 is the LSB. (Monitoring the logic
status of external input terminals)
C0-27
Output Terminal Status
*
*
*
*
R1 Y2 Y1
0
0
0
0
0
0
0
Y1 is the LSB. (Monitoring the logic
status of output terminals)
C0-28
VS Input Monitoring
0-10000
C0-29
IS Input Monitoring
0-10000
C0-30
VF Input Monitoring
0-10000
C0-31
IF Input Monitoring
0-10000
Section 2 Advanced Parameters
8.8
F6 Group: Simple PLC Function
8.8.1
Options of Program Operation Mode and Time Unit
No.
Function
Range
Unit Default Type
F6-00
Program Operation
Mode
Ones place: Options of programmable
speed operation mode
0: Monocycle
1: Run as per Preset Speed 7 after
monocycle
2: Limited times of continuous cycle
3: Continuous cycle
Tens place: Not used
Hundreds place: Not used
Thousands place: Options of restart
after operation paused
0: Restart from the section when it
paused
1: Restart from Preset Speed 1
Ten thousands place:
Program operation time unit
0: S 1: min
00000
〇
F6-15
Speed Cycling Times 1
~
10000
1
●