User Manual
EM303B General Purpose Inverter
104
19
DC Bus Voltage
DC Bus
Voltage at 1.5
Times Rated
Input Voltage
Calculate the percentage= (DC bus voltage / the
DC bus voltage at 1.5 times rated input
voltage)*100%*A as the analog output
20
Output Power
inverter rated
power
Calculate the percentage= (output power / rated
power of inverter)*100%*A as the analog output
21
Feedback frequency
/Output torque
Fmax/Motor
rated torque
Feedback frequency output in speed mode, take
the percentage of output frequency over the
maximum frequency (Fmax) and then convert it
to analogoutput. Torque output in torque mode,
takes the percentage of output torque over motor
rated torque and then converts it to analog output
1. In order to meet different needs of meters and external devices, the actual full
scale voltage of M0/M1 is 10.9V, and the actual full scale current is 22mA.
2. Default of M0 and M1 is 0
~
10V.
3. If there is high demand for accuracy of analog output in application, please check idling
output of M0 and M1 with multi-meter.