9.2 MOUNTING QUESTIONS
*What kind of equipment do I need for mounting the WTMD?
All tooling and accessories for the mounting are included. You can mount without any extra
equipment except an electric stroked drill. See section 2.2
*May I fix it from the top or the sides to other utilities?
This is an electronic equipment, so no procedures can be made such as cutting its panels or case or
drilling it in order to stable or any other means.
Otherwise warranty will be void. When necessary to
fix your WTMD from the top or the sides, it would be best to fasten gently without harming it.
*Is it possible to use WTMD without fixing it to the ground?
It is not advised to operate WTMD which will be confronted to constant hits and bumps, without
fixing it to the ground. Serious bumps may cause it to fall down.
*Would relocating the WTMD cause any failure?
Following the mounting and dismounting procedures in the user’s manual would not cause any
failure.
*Are there any restrictions for the place of the mounting?
You should mount your WTMD as in the necessary distance, away from moving metal objects. This
distance should at least be 1 meter depending on the type of the moving metal.
Also the environmental conditions should match with the security class of your WTMD. See section
2.1
*Is it possible to have the mains input from Top to Bottom or Bottom to Top
?
In general the standard mains input for
ThruScan
s3/sX/sX-i/sX-WP
’s is from top, for
ThruScan
s9
is at the bottom of the side panel.
To replace:
To have the mains input to the bottom of
ThruScan
s3/sX/sX-i/sX-WP
, mains cable should be
guided from the edge of the panels near to the dark alarm lights towards the bottom.
The mains cable may be connected to the power supply module inside the control unit directly by
drilling a hole on the back of the control unit for
ThruScan
s9
. Drilling a hole on the back of the
control unit does not abolish the principle of never drilling any part of the WTMD. If the desired
location for the mains input on the WTMD is clarified prior to the order, the mains input may be
arranged to be on the desired point if allowed.
* How can I operate multi WTMDs together?
To operate your WTMDs in parallel, you should follow the instructions in Section 6.13 If there is no
specific provided cable then a twin cable should be connected from outputs 1 and 2 via the proper
connectors between the sockets of the
ThruScan
s as shown in
Section 3.7.
2
1
2
1
Do not forget to turn OFF the switch on the main card of the slave
WTMD. See Section 6.13
40