4.1.11 ENVIRONMENT NOISE LEVEL
ENVIRONMENT NOISE
LEVEL
ENVIRONMENT NOISE
LEVEL
NOISE = 000
This MENU is prepared to measure the electromagnetic noise level of
surrounding and thus help the user to select the sensitivity level
accordingly.
1-
Press
UP&DOWN
buttons until the
ENVIRONMENT NOISE
LEVEL sub-
MENU option is displayed.
2-
Enter the MENU by pressing
SEL(
√
)
button,
3-
The noise value of the environment will be displayed,
4-
Return to MENU by pressing
RUN(X).
NOTE: People carrying metal objects must not pass through or near the WTMD while
carrying out this process.
A higher value than the threshold noise level should be selected for sensitivity level to
avoid false alarms depending the users experience and instinct.
4.1.12 PASS SENSOR
(
*for only
ThruScan
sX-i
)
ThruScan
operate to detect only the passing metal metals through archway. With this extra
feature it is possible to delete this function.
To realize this;
PASS SNSR
Y<==>N
1-
Find
“PASS SNSR”
sub
-MENU by
UP&DOWN
buttons,
2-
Enter the MENU by pressing
SEL(
√
)
button,
3-
Select your alternatife by
UP&DOWN
buttons as;
*
N
(no) To shut PASS SNSR.(passing is not necessary for
detection) or vice versa.
PASS SNSR
Y<==>N
ACTIVE = Y
4-
Return to MENU by pressing
RUN(X)
.
Press
UP&DOWN
buttons and change to the next
sub
-MENU option or press
RUN(X)
button to
store the changes and thus return to the normal operating mode.
4.1.13 ALARM TONE DURATION SELECT
(
*only for
ThruScan
sX-i
)
You may adjust the alarming tone period. This period can be between 0,5 to 2 seconds.
To adjust this period;
ALARM DURATION
1-
Press
UP&DOWN
buttons to find
“ALARM DURATION”
sub
-MENU,
2-
Enter to MENU by
SEL(
√
)
buton,
3-
Select your alternatif by
UP&DOWN
butons,
4-
Return to MENU by pressing
RUN(X).
Press
UP&DOWN
buttons and change to the next
sub
-MENU option
or press
RUN(X)
button to store the changes and thus return to the normal operating mode.
ALARM DURATION
[05]